101497

INSTALLATION

Inlet Connector

Hose

Figure 4 - Hose and Inlet Connector

1. Provide propane supply system (see Propane Supply, page 5).

2. Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL

fitting counterclockwise into threads on tank. Tighten firmly using
2.22 cm (7/8 inch) wrench.

IMPORTANT:

Position regulator so that hose

leaving the regulator is in a horizontal position (see Figure 3). This places the
regulator vent in the proper position to protect it from the weather.

WARNING ICON

G 001

WARNING

Review and understand the warnings in the Safety Information
Section, pages 2 and 3. They are needed to safely operate this
heater. Follow all local codes when using this heater.

3. Connect hose to inlet connector. Tighten firmly using a wrench.

IMPORTANT:

Use extra hose or piping if needed. Install extra hose or piping

between hose/regulator assembly and propane tank. You must use the regula-
tor supplied with heater.

Propane
Tank

Propane
Supply
Valve

Regulator

Hose

POL Fitting

Figure 3 - Regulator Position

WARNING ICON

G 001

WARNING

Test all gas piping and connections for leaks after installing
or servicing. Never use an open flame to check for a leak.
Apply a mixture of liquid soap and water to all joints.
Bubbles forming show a leak. Correct all leaks at once.

Advertising