Adjustment of coverage area, Specifications, Mode switching summary – Heath Zenith Carriage Light with Motion-activated Sensor 52-4477-8 Manuel d'utilisation

Page 6

Advertising
background image

6

598-1285-00

aDJuStMent OF COveraGe area

The sensor on this light fixture detects “motion”

by the movement of heat across the coverage

area. However, following are examples of objects

that also produce heat and can cause the sensor

to trigger:

• Pools of Water • Air Conditioners

• Dryer Vents

• Animals

• Heating Vents • Automobile Traffic

If you suspect that a heat source of this type is

triggering the sensor, reduce the sensitivity.

SPeCiFiCatiOnS

Range ............................................. Up to 30 ft. (9.1 m) [varies with surrounding temperature].

Sensing Angle................................. Up to 150°, 240° adjustable

Electrical Load ............................... Up to 100 Watt Maximum Incandescent

Bulb Type ....................................... Medium Base, Type “A”, 100 Watt Maximum

Sensor Capacity .............................. Up to 500 Watt (4.1 A) Maximum

Power Requirements ....................... 120 VAC, 60 Hz

Operating Modes ........................... TEST, AUTO, and MANUAL MODE

ON-Timer ...................................... 1, 5, 10 minutes

Test Timer ...................................... 5 Seconds

Manual Mode Timer ...................... Dusk-to-Dawn

MANUAL MODE

AUTO

TEST

ON-TIME Switch at 1, 5, or 10

minutes

MODe SWitCHinG SuMMary

Flip light switch off for

one second then back

on*

* If you get confused while switching modes, turn

the power off for one minute, then back on. After

the calibration time the control will be in the AUTO

mode.

Advertising