Homelite HHC35A Manuel d'utilisation

Page 9

Advertising
background image

9

100577

4. Plug heater’s power cord into approved, grounded, three-wire extension cord.

Extension cord must be at least six feet (1.8 meters) long.

Extension Cord Size Requirement

6 to 10 feet (1.8 to 3 meters) long, use 18 AWG (0.75 mm

2

) rated cord

11 to 100 feet (3.3 to 30.5 meters) long, use 16 AWG (1.0 mm

2

) rated cord

101 to 200 feet (30.8 to 61 meters) long, use 14 AWG (1.5 mm

2

) rated cord

5. Plug extension cord into standard 120 volt/60 hertz, 3-prong grounded outlet.

Heater will start when extension cord is plugged into outlet. If not, push in
heater’s flame-out control reset button (see Figures 6 and 7).

Figure 7 - Flame-Out Control Reset Button, 100/150 Models

Figure 6 - Flame-Out Control Reset Button, 35 Model

Flame-Out
Control
Reset
Button

To Stop Heater

1. Unplug extension cord from outlet.

To Restart Heater

1. Wait two minutes after stopping heater.
2. Repeat steps under “To Start Heater”.

Flame-Out
Control
Reset
Button