Alternate wiring (for heat pumps only) – Honeywell RTH 7000 Manuel d'utilisation

Page 14

Advertising
background image

Installation Guide



Leave metal jumper in place, connecting

R & Rc terminals.
If your old thermostat had both V and VR

wires, stop now and contact a qualified

contractor for help.
If your old thermostat had separate O and B

wires, attach the B wire to the C terminal. If

another wire is attached to the C terminal,

stop now and contact a qualified contractor

for help.
If your old thermostat had Y1, W1 and W2

wires, stop now and contact a qualified

contractor for help.

If L terminal is used, C terminal wire must be

connected (contact a contractor if there is

no C wire).
If E and Aux terminals do not each have a

wire connected, use a small piece of wire to

connect them to each other.

Alternate wiring (for heat pumps only)