Electric requirements – canada, Warning, If connecting by direct wire – Whirlpool 29 Inch Electric Dryer Owners Guide Manuel d'utilisation
Page 10: Grounding instructions, Save these instructions

�
This
dryer
is
equipped
with
a
UL-listed
and/or
CSA
International
Certified
Power
Cord
intended
to
be
plugged
into
a
standard
14-30
R
wall
receptacle.
The
cord
is
5
ft
(1.52
m)
long.
Be
sure
wall
receptacle
is
within
reach
of
dryer’s
final
location.
�
If
codes
permit
and
a
separate
ground
wire
is
used,
it
is
recommended
that
a
qualified
electrician
determine
that
the
ground
path
is
adequate.
�
Do
not
use
an
extension
cord.
For
further
information,
or
to
obtain
a
Power
Supply
Cord
Replacement,
please
reference
the
contact
information
listed
on
your
Quick
Start
Guide.
10
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
�
Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), covered with flexible metallic conduit. All
current-carrying wires must be insulated.
�
10-gauge solid copper wire (do not use aluminum) at least
5 ft (1.52 m) long.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected appliance:
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for
electric current. This appliance is equipped with a cord having
an equipment-grounding conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in
doubt as to whether the appliance is properly grounded. Do
not modify the plug provided with the appliance: If it will not fit
the outlet, have a proper outlet installed by a qualified
electrician.
For a permanently connected appliance:
This appliance must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on
the appliance.
SAVE THESE INSTRUCTIONS
Electric Requirements – Canada
WARNING
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
It is your responsibility:
�
To
contact
a
qualified
electrical
installer.
�
To
be
sure
that
the
electrical
connection
is
adequate
and
in
conformance
with
Canadian
Electrical
Code,
C22.1–latest
edition
and
all
local
codes.
A
copy
of
above
codes
standard
may
be
obtained
from:
Canadian
Standards
Association,
178
Rexdale
Blvd.,
Toronto,
ON
M9W
1R3
CANADA.
�
To
supply
the
required
4-wire,
single-phase,
120/240
V,
60
Hz
AC
only
electrical
supply
on
a
separate
30
A
circuit,
fused
on
both
sides
of
the
line.
A
time-delay
fuse
or
circuit
breaker
is
recommended.
Connect
to
an
individual
branch
circuit.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected appliance:
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for
electric current. This appliance is equipped with a cord having
an equipment-grounding conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in
doubt as to whether the appliance is properly grounded. Do
not modify the plug provided with the appliance: if it will not fit
the outlet, have a proper outlet installed by a qualified
electrician.
SAVE THESE INSTRUCTIONS
4-wire
receptacle