Ip system troubleshooting sequence – Empire Comfort Systems FAW-40-1IP Manuel d'utilisation

Page 14

Advertising
background image

12427-2-0903

Page 14

SmartValve™ System Troubleshooting Sequence
Note: Before Troubleshooting, Become Familiar

with the Sequence of Operation

IP SYSTEM TROUBLESHOOTING SEQUENCE

NO

NO

NO

YES

YES

NO

• Turn OFF Gas Supply
• Disconnect System Control

Harness

• Set Thermostat to Call for

Heat

Plug Harness into SmartValve
Control
Wait for Internal Check Delay
(SV9501)

Igniter Warms UP and
Glows Red

System is Okay

Main Valve Opens and
Main Burner Lights

• Turn On Gas Supply
• Pilot Burner Lights

Check for Proper Voltage at
Control Harness (See Inset A
-Voltage Should be 24V
Between Thermostat and
24V Common, and 24V
Between 24V Common and
24V Hot.)

Reconnect Pilot Burner Cable

• Check that Pilot Gas is Flowing

Wait to Assure Pilot Gas Tubing
is Purged.

Replace Igniter/Flame Rod Assembly

Note: Igniter Will Cycle OFF
and Back ON Once During
the 90 Second Ignition Trial

Cycle Thermostat OFF and Back ON

Main Burner Lights

Replace SmartValve Control

Check Transformer and Line
Volt Supply

• Check that Pilot Flame Makes Good

Contact with Pilot Burner Flame
Rod

• Check for Good Electrical

Connection Through the Pilot
Tubing

• If Both of the Above are Good,

Replace Igniter/Flame Rod

• Measure Voltage Between 24V Hot

and 24V Common Leads to
SmartValve Control. Must Measure
at Least 19.5 VAC with Igniter
Powered. See Inset A to Identify
Proper Lead. This Check Must be
Done with the SmartValve Control
Connected and Igniter Powered.

Unplug Pilot Burner Cable.
Measure Voltage at SmartValue
HSI Element Output (See Inset B)
24V Nominal

YES

NO

NO

NO

NO

YES

YES

YES

YES

CHECK
• Line Voltage Power
• Low Voltage Transformer
• Limit Controller
• Thermostat
• Wiring

Replace SmartValve Control

Replace SmartValve Control

START

Replace Igniter/Flame Rod Assembly

Reconnect Pilot Burner Cable

INSET A

24Volt
Thermostat

24
Volts

24 Volt
Common

24

Volts

24 Volt
Hot

EFT
Output

End View
of Control
Harness
Connector

INSET B

HSI
Terminals

Advertising
Ce manuel est liée aux produits suivants: