Service procedures – Desa BC40 Manuel d'utilisation

Page 9

Advertising
background image

www.desatech.com

9

111168-01A

SERVICE PROCEDURES

WARNING: To avoid risk of

burn and electrical shock, never

attempt to service heater while it

is plugged in, operating, or hot.

UPPER SHELL REMOVAL

1. Remove screws along each side of heater using

5/16" nut-driver. These screws attach upper

and lower shells together. See Figure 7 or 8.

2. Lift upper shell off.
3. Remove fan guard.

Screw

Upper Shell

Fan Guard

Figure 7 - Upper Shell Removal

(40/55T/70T Models Only)

Screw

Upper Shell

Fan Guard

Figure 8 - Upper Shell Removal

(115T/165T Models Only)

Figure 9 - Fan, Motor Shaft, and

Setscrew Location

Flush

Fan

Setscrew

Motor Shaft

Motor

Figure 10 - Fan Cross Section

Setscrew

Motor Shaft

Fan

FAN

IMPORTANT:

Remove fan from motor shaft

before removing motor from heater. The weight

of the motor resting on the fan could damage the

fan pitch (see Figure 9).
1. Remove upper shell (see Figure 7 or 8).
2. Use 1/8" allen wrench to loosen setscrew

which holds fan to motor shaft.

3. Slip fan off motor shaft.
4. Clean fan using a soft cloth moistened with

kerosene or solvent.

5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place fan hub flush

with end of motor shaft (see Figure 10).

7. Place setscrew on flat of shaft. Tighten

setscrew firmly (40-50 inch-pounds/4.5-

5.6 n-m).

8. Replace fan guard and upper shell.

Advertising