Troubleshooting, Warning: high voltage – Desa BC40 Manuel d'utilisation

Page 8

Advertising
background image

www.desatech.com

111168-01A

8

TROUBLESHOOTING

WARNING: Never service heater while it is plugged in, operating,

or hot. Severe burns and electrical shock can occur.

REMEDY

1. Check circuit breaker in elec-

trical panel

2. Turn thermostat knob to a

higher setting

3. Check all electrical connec-

tions. See Wiring Diagrams,

page 15

4. If fan does not turn freely, see

Pump Rotor, page 14

5. Replace ignition control as-

sembly

6. Replace motor

1. Fill tank with kerosene

2. See Pump Pressure Adjust-

ment, page 10

3. See Fuel Filter, page 11

4. See Nozzle Assembly, page 12

5. Drain and flush fuel tank with

clean kerosene. See Storing,

Transporting, or Shipping,

page 7

6. Check electrical connections.

See Wiring Diagrams , page 15

7. Replace ignitor, see page 11

8. Replace ignition control as-

sembly

1. See Pump Pressure Adjust-

ment, page 10

2. See Air Output, Air Intake, and

Lint Filters, page 10

3. See Fuel Filter, page 11

4. See Nozzle Assembly, page 12

5. Make sure photocell boot is

properly seated in bracket

6. Clean photocell lens

7. Check electrical connections.

See Wiring Diagrams, page 15

8. Replace photocell

9. Replace ignition control as-

sembly

POSSIBLE CAUSE

1. No power to heater

2. Thermostat setting is too low

3. Bad electrical connection be-

tween motor and ignition con-

trol assembly or ignition control

assembly and power cord

4. Binding pump rotor

5. Defective ignition control as-

sembly

6. Defective motor

1. No fuel in tank

2. Pump pressure incorrect

3. Dirty fuel filter

4. Obstruction in nozzle

5. Water in fuel tank

6. Bad electrical connection

between ignitor and ignition

control assembly

7. Defective ignitor

8. Defective ignition control as-

sembly

1. Pump pressure incorrect

2. Dirty air intake, air output,

and/or lint filter

3. Dirty fuel filter

4. Obstruction in nozzle

5. Photocell assembly not properly

installed (not seeing the flame)

6. Dirty photocell lens

7. Bad electrical connection be-

tween photocell and ignition

control assembly

8. Defective photocell

9. Defective ignition control as-

sembly

FAULT CONDITION

Motor does not start five seconds

after heater is plugged in

Motor starts and runs but heater

does not ignite

Heater ignites but ignition control

assembly shuts heater off after a

short period of time

WARNING: High voltage!

WARNING: High voltage!

WARNING: High voltage!

Advertising
Ce manuel est liée aux produits suivants: