1) All wiring must comply with local and national electrical codes and be installed by a

qualified electrician. If you have any questions regarding the following instructions,

contact a qualified electrician.

2) Check available power supply and resolve any wiring problems BEFORE installation

and operation of this unit.

3) For your safety and protection, this unit is grounded through the power cord plug

when plugged into a matching wall outlet. If you are not sure whether the wall outlets

in your home are properly grounded, please consult a qualified electrician. DO NOT

USE PLUG ADAPTERS OR EXTENSION CORDS.

4) The manufacturers nameplate is located on the rear wall of the water tank

compartment. The nameplate contains electrical and other technical data specific to

this unit.

5) To avoid the possibility of personal injury, always disconnect the power supply

before attempting to clean and/or service the unit.

Model Number:

DDR2509EE

Dehumidifying Capacity (Pints / Liters)

25 / 11.8

Electrical Requirements

115 Volts / 60 Hz

Power Input (Watts)

380

Rated Amperage (Dehumidifying)

3.8

Air Flow Circulation- High Fan Speed
(Cubic Feet per Minute)

180

Type of Refrigerant

R22

Water Tank Capacity (Pints / Liters)

5 / 10.55

Operating Noise Level (dB A)

52

Unit Dimensions (Width x Height x Depth)

13

6

/

16

x 19

15

/

16

x 10

Net Weight (kg / lbs)

15 / 33.1

NOTE: Specifications are subject to change without notice, for further improvements.

ELECTRICAL SPECIFICATIONS

DDR3009EE

30 / 14.2

115 volts / 60 Hz

420

4.2

180

R22

5 / 10.55

52

13

6

/

16

x 19

15

/

16

x 10

15 / 33.1

DDR4009EE

40 / 18.9

115 volts / 60 Hz

525

4.8

180

R22

5 / 10.55

54

13

6

/

16

x 19

15

/

16

x10

15 / 33.1

UNIT SPECIFICATIONS