Service procedures, Warning – Desa 50 Manuel d'utilisation

Page 12

Advertising
background image

12

099618

Fan Guard

Upper Shell

WARNING

To avoid risk of burn and electrical shock, never attempt
to service heater while it is plugged in, operating or hot.

Upper Shell Removal

1. Remove screws along each side of

heater using 5/16" nut-driver. These
screws attach upper and lower
shells together.

2. Lift upper shell off.
3. Remove fan guard.

SERVICE

PROCEDURES

Air Output
Filter

Lint Filter

Air Output
Filter

Lint Filter

Air Intake
Filter

Filter End
Cover

Fan
Guard

Figure 11 - Air Output, Air Intake,
and Lint Filters, 35/50/70 Models

Figure 12 - Air Output, Air Intake,
and Lint Filters, 100/150 Models

Filter End
Cover

Air Intake
Filter

Fan

IMPORTANT:

Remove fan from motor

shaft before removing motor from
heater. The weight of the motor resting
on the fan could damage the fan pitch.

1. Remove upper shell (see above).
2. Use 1/8" allen wrench to loosen

setscrews which holds fan to motor
shaft.

3. Slip fan off motor shaft.
4. Clean fan using a soft cloth

moistened with kerosene or solvent.

5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place

fan hub flush with end of motor
shaft (see Figure 10).

7. Place setscrews on flat of shaft.

Tighten setscrews firmly (40-50
inch-pounds/4.5-5.6 n-m).

8. Replace fan guard and upper shell.

Fan

Motor
Shaft

Figure 10 - Fan Cross Section

Fan

Setscrews

Motor
Shaft

Figure 9 - Fan, Motor Shaft,
and Setscrew Location

Setscrews

Air Output, Air Intake and
Lint Filters

1. Remove upper shell (see above).
2. Remove filter end cover screws

using 5/16" nut-driver.

3. Remove filter end cover.
4. Replace air output and lint filters.
5. Wash or replace air intake filter (see

Preventative Maintenance Schedule,
page 10).

6. Replace filter end cover.
7. Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters.

Fan Guard

Figure 8 - Upper Shell Removal

Flush

Advertising