Installation, Gas hook-up, Lp tank requirements – DCS BGB132 Manuel d'utilisation

Page 13: Natural gas hook-up (continued), Lp gas hook-up

Advertising
background image

11

INSTALLATION

GAS HOOK-UP

LP TANK REQUIREMENTS

A dented or rusty LP gas cylinder may be hazardous and

should be checked by your LP supplier. Never use a cylinder
with a damaged valve.

The LP gas cylinder must be constructed and marked in

accordance with the specifications for LP gas cylinders of the
U.S. Department of Transportation (DOT ) and designed for
use with a Type 1 system only.

Do not change the regulator/hose assembly from that

supplied with the unit or attempt to use a Type 1 equipped
regulator/hose assembly with a standard 510 POL tank/valve
assembly. The cylinder must be provided with a shut-off
valve terminating in an LP gas supply cylinder valve outlet
specified, as applicable, for connection Type 1.

If the appliance is stored indoors, the cylinder must be

disconnected and removed from the appliance.

Cylinders must be stored outdoors in a well ventilated area

out of the reach of children.

Gas cylinder supply must be turned off when not in use.

NATURAL GAS HOOK-UP (continued)

To hook-up the fittings supplied with the side burner, assemble as shown in Fig.04. Use joint compound on
male threads only.

Do not use joint compound on the flare end of the 1/2” NPT
to 3/8” flare adapter. Ensure that the regulator arrow points
in the direction of gas flow-towards the unit, away from the
supply.

Do not forget to place the installer-supplied gas valve in an
accessible location.

LP GAS HOOK-UP

CONNECTION: 1/2” NPT male with 3/8” flare adapter
(included). Use 90º elbow 1/2” NPT with 3/8” flare
(P/N 212394) for side mount models only when installing on
the cart. Use sealer on 1/2” NPT threads only.

OPERATING PRESSURE: 10.0” W.C. side burner uses the LP
regulator from adjoining grill.

SUPPLY PRESSURE: 11” to 14” W.C.

Apply joint compound to the threaded end of the side burner gas
inlet and tighten the adapter to the pipe. Assemble the 24” and 30” hoses to the 3/8” flare tee, as shown in
Fig.05. Tighten the regulator hose to the remaining fitting of the 3/8” flare tee.

Open Top

Manifold

Bottom of
131 &132 Burner

1/2" Coupling

1/2" NPT x 2.0”
Nipple

1/2" NPT to 3/8"

Flare Adapter

Regulator

To Gas Supply

1/2" NPT x 2.0”
Nipple

FIG. 04 Natural Gas

FIG. 05 LP Gas

Advertising