Operation – Danby DPAC5009 Manuel d'utilisation

Page 6

Advertising
background image

REMOTE CONTROL FEATURES:

POWER CONTROL: The power control turns

the unit on and off.

MODE CONTROL: The mode control has 4

settings: Cool, Dehumidifiy, Fan, Auto. The settings

are adjustabed by the Mode Control button.

COOLING MODE: During the cooling mode,

the air is cooled and hot air is exhausted outside

through the exhaust tube. Adjust fan speed and temper-

ature to suit your desired comfort level.

Note: The air exchange hoses must vent outside the

room when using Cool mode.

DEHUMIDIFY MODE: Air is dehumidified as

it passes through the air conditioner, without being in

full cooling mode. If room temperatures is higher than

25°C (77°F), fan speed can be adjusted;

otherwise fan speed is fixed to “low”.

FAN MODE: Air is circulated throughout the

room with no cooling.

Note: Unit does not need to be vented in Fan mode.

AUTO MODE: In auto mode the unit will

switch mode and fan speed automatically based on the

ambient temperature.

LCD DISPLAY FEATURES:

FAN SPEED CONTROL: The fan speed

control has 4 settings: Auto (Cooling only), High,

Medium, and Low.

TEMP. SET CONTROLS :

The temperature can be set by means of the

and

buttons on the remote control. The temperature can be

set between 16°C (61°F ) and 32°C (89°F). Pressing

the

and

buttons will cause the set temperature to

remain in the display panel for approximately 5

seconds. The display will then revert back to showing

the current room temperature.

Note: It is only possible to set the temperature when in

COOLING MODE. The temperature can not be set

when in AUTO, DEHUMIDIFYING or FAN mode.

FAHRENHEIT / CELSIUS SELECTOR:

Pressing this button will switch the display between

degrees Celsius and degrees Fahrenheit. Note: Initial

setting is °C

TIMER SETTING CONTROL: Press the

Timer button on the remote control to set the timer.

The ON or OFF logos (depending on timer modes “A”

or “B” below) will appear in the display panel, and the

clock symbol will flash for approx. 10 seconds; the

display panel will show a time of 8 hrs. While the

clock symbol is flashing, press the

and

buttons

on the remote control to select the time (in hours

between 00 and 24) for either of the timer modes “A”

or “B” (see below). The time selected will be shown on

the display panel and after approximately 10 seconds,

the clock symbol will remain illuminated together with

either the ON or OFF logo.

Timer Mode A) Auto Turn Off: With the machine on

and running, set the timer to select the number of hours

you would like the unit to run until it automatically

shuts off. The set time will be shown in the display

together with the clock symbol and the OFF logo.

Tiimer Mode B) Auto Turn On: Switch the machine

on using the ON / OFF button (either on the machine

itself or on the remote control) so that the machine is

running and the desired mode is selected. Press the

ON/OFF button again to put the machine into stand-by

mode. Set the timer to select the number of hours until

it is required for the machine to start up automatically.

The set time will be shown in the display together with

the clock symbol and the ON logo.

TIMER CANCEL CONTROL: If the time has

been set as in either “A” or “B” above and it is then

decided that the timer is not required, pressing the

CANCEL button will turn the timer off.

LCD DISPLAY SYMBOLS:

Auto mode

Cooling mode

Dehumidify mode

Fan only mode

High fan speed

Med. fan speed

Low fan speed

Display set temperature

Display timer setting of auto switch on/off

OPERATION

5

On/Off
Switch

LCD
Display

Advertising
Ce manuel est liée aux produits suivants: