Figure 19 - 10 Foot Rule

10 FOOT RULE

All flue gas outlet chimney terminations must
extend a minimum of 3 feet in height above
highest point where it passes through roof and
must be at least 2 feet above highest point of
the roof that is within a horizontal distance of
10 feet (see Figure 19).

VenTIng InsTallaTIon

Continued

FINISHING THE FIREPLACE

Combustible materials, such as wallboard,
gypsum board, sheet rock, drywall, plywood,
etc. may make direct contact with sides and
top around the fireplace face. It is important
that combustible materials do not overlap face
itself. Brick, glass, tile or other noncombustible
materials may overlap front face provided
they do not obstruct essential openings such
as louvered slots. When overlapping with
a noncombustible facing material, use only
noncombustible mortar or adhesive.

30E-8DM

EFFECTIVE HEIGHT
OF TERMINATION CAP

EFFECTIVE HEIGHT
OF TERMINATION CAP

EFFECTIVE HEIGHT
OF TERMINATION CAP

EFFECTIVE HEIGHT
OF TERMINATION CAP

MINIMUM
HEIGHT

14.5 FT.

MINIMUM

UP TO
6FT. MAX.

UP TO
6FT. MAX.

HEIGHT

14.5 FT.

MIN. HEIGHT
OF 22 FT. (WITH
2 ELBOW SETS)
MAX. HEIGHT OF
50 FT.

MAX. HEIGHT
50 FT.
(ANY SYSTEM)

30E-8DM

Figure 20 - Typical Residential Installations