Operating instructions – Danby DDR2509EE Manuel d'utilisation

Page 5

Advertising
background image

1) LED Readout (ROOM HUMIDITY): The LED

window displays the following information

independently:

A) Internal (Room/Environment) Relative Humidity

Conditions

B) Set Operating Relative Humidity Value.

NOTE: The LED readout is programmed to default to

display the ambient relative humidity conditions.

To view the Set Operating Relative Humidity Value,

press the “up” or “down” button (once) and the set RH

operating value will flash for approximately 5 seconds in

the LED window, then revert back to display the internal

RH value.

2) ON/OFF Button: Each time this button is pressed the

unit turns ON (adjacent indicator light illuminates) or Off

(adjacent indicator light is not illuminated)

3) CONTINUOUS: Used for Continuous Dehumidifier

Operation (unit will run non-stop).

NOTE: Humidity values (settings) cannot be

programmed in this mode. The adjacent (green) indicator

light illuminates to signify the “continous” mode is

currently in operation.

4) HUMIDITY UP: This button allows you to increase

the relative humidity setting. Each time this button is

pressed, the RH value setting is increased incrementally

by 5% (ranging from 35% - 80%)

5) HUMIDITY DOWN: This button allows you to

decrease the relative humidity setting. Each time this

button is pressed the RH value setting is decreased

incrementally by 5% (ranging from 80% - 35%).

6) HIGH FAN: The adjacent (green) indicator light

illuminates when HIGH FAN is selected.

7) LOW FAN: The adjacent (green) indicator light

illuminates when LOW FAN is selected.

8) WATER FULL INDICATOR: This (red) light

illuminates under the following conditions:

A) When the internal water tank is not properly installed

inside the cabinet.

B) When the internal water tank is full. The water tank

must be emptied and replaced back in the cabinet before

normal operating conditions can resume.

OPERATING INSTRUCTIONS

1

2

3

8

6

7

4
5

4

INDICATOR

LIGHT FUNCTION

Power Light (Green):

When the unit is first connected to an electrical outlet,

the (green) power light will not light until the “on/off”

button is pressed. When the “on/off” button is activated,

the power light turns to a state “on” condition. The

dehumidifier will automatically default to the memory

setting (see Memory Setting below for details).

IMPORTANT NOTE: Depending on the humidity

conditions of the surrounding environment, the

dehumidifier may not start automatically when the

“on/off” button is pressed (see dehumidifier operating

instructions for details). In the event of a power failure,

the unit will default to the last program setting that was

used when power is restored.

Water Full Indicator Light (Red):

When the water tank is full and/or incorrectly positioned

inside the cabinet, the (water full) red light turns on and

remains on until such time the tank is emptied and/or

correctly re-positioned. This condition will result in the

immediate shut down of the dehumidifying system (both

compressor and fan motor operation are terminated).

This is a safety feature. When the water tank is emptied

and/or correctly re-positioned, the dehumidifier will

resume operation automatically. NOTE: It may take

several minutes before operating conditions resume.

Factory Default Setting: Each time the unit is

disconnected /re-connected and/or in the event of a

power failure, the electronic circuit board automatically

defaults to the following factory setting:

Humidity Setting: 60%

Fan Speed: High

NOTE: In the event of a power failure, all previous

settings are automatically erased/cancelled. If your

program setting was different than above (default setting)

it will be necessary to re-program your settings. When

the unit is switched “off” manually (using the on/off

keypad) the unit will always default to the last program

setting that was used.

Advertising
Ce manuel est liée aux produits suivants: