Installation – DCS ES36 EN Manuel d'utilisation

Page 12

Advertising
background image

10

INSTALLATION

WALL MOUNT INSTALLATION

Calculating Installation Height – Installation height for a standard 8 ft high kitchen ceiling is shown

below in Figure X. The minimum installation height allowed is 30”. Typical installations are between
30” and 36”.

Use the following formula to calculate installation height:

Installation Height = (Ceiling Height) – (Height Cooktop Surface) – (Hood Height) –

(Duct Cover Height)

(Example: Installation height = 96” – 36”– 18” – 12” = 30”)

Hood Height = 12” for ES30 and ES36 models

18” for VS30, VS36, VS1236 and VS48 models

Duct Cover Height – Duct cover accessories are available in 6” or 12” heights. For taller
ceilings duct covers can be joined together in any combination.

1. Hood Installation Height

After the hood installation height has been determined, draw a horizontal line at a distance above
the cooktop equal to the desired hood installation height plus dimension “E” (see Table on
Figure 4).

This line is the mounting location of the wooden bracket shipped with the hood.

2. Find the centerline of the cooktop. Draw a vertical line along this centerline up to the horizontal line

drawn in step 1.

3. The hood is mounted to the wall using a wooden bracket shipped with the hood. Remove the

bracket from the hood by removing two shipping screws. Mark the centerline of the bracket.

8 ft

(96")

30" to 36"
recommended

12" or

18"

12"

36"

Duct Cover Height

Hood Height

Ceiling Height

Cooking Surface Height

Installation Height Figure X

Installation Height

Advertising