Important Safety Information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

ELECTRICAL
SPECIFICATIONS

FOR YOUR SAFETY: Read these instructions carefully before operating the unit.

1) All wiring must comply with local and national electrical codes and must

be installed by a qualified electrician. If you have any questions
regarding the following instructions, contact a qualified electrician.

2) Check available power supply and resolve any wiring problems

BEFORE installing and operating this unit.

3) This 115V air conditioner uses 10.2 or less nameplate amps and may

be used in any properly wired, general purpose household receptacle.
See Table 1 for specifications for individual branch circuit.

4) For your safety and protection, this unit is grounded through the power

cord plug when plugged into a matching wall outlet. If you are not sure
whether your wall outlet is properly grounded, please consult a qualified
electrician.

5) The wall outlet must match the 3-prong plug on the service cord

supplied with the unit. DO NOT use plug adapters. See Table 2 for
receptacle and fuse information. If it is necessary to use an extension
cord to connect your air conditioner, use an approved “air
conditioner” extension cord only
(available at most local hardware
stores).

6) The rating plate on the unit contains electrical and other technical data.

The rating plate is located on the right side of the unit, above the power
cord.

3

TABLE 1

Suggested Individual Branch Circuit

Nameplate Amps

*AWG Wire Size

8.8 to 10.2

14

AWG- American Wire Gauge

*Based on copper wire at 60°C temperature rating.

TABLE 2

Receptacle and Fuse Types

Rated Volts

125

Amps

15

Wall Outlet

Fuse Size

15

Time Delay Fuse

Plug Type

(or Circuit Breaker)