Typical compressed air distribution system – Craftsman 919.724271 Manuel d'utilisation

Page 12

Advertising
background image

12- ENG

D25050

DRAIN

TRAP

DRAIN

TRAPS

DRAIN

LEGS

MOISTURE

SEPARATOR

AND TRAP

DIRT

LEG

DIRT

LEG

LUBRICATOR

REGULATOR

FILTER

AIR DISCHARGE

VALVE

LUBRICATOR

MAIN DISTRIBUTION AIR LINES
Slope pipe in direction of air flow.
Water condensate flows along
bottom of pipe to drain legs,
preventing it from entering feeder
lines.

REGULATOR

FLEXIBLE

COUPLING

DRAIN COCK

VALVE

TYPICAL COMPRESSED

AIR DISTRIBUTION SYSTEM

AIR FLOW

AIR FLOW

FEEDER LINES SLOPE

WITH AIR FLOW

AIR USAGE

LINES

AIR

COMPRESSOR

Use pipe that is the same size as
the air tank outlet. Piping that is
too small will restrict the flow of
air.

If piping is over 100 feet long,
use the next larger size.

Bury underground lines below
the frost line and avoid pockets
where condensation can gather
and freeze. Apply pressure
before underground lines are
covered to make sure all pipe
joints are free of leaks.

A flexible coupling is
recommended to be installed
between the air discharge outlet
and main air distribution line to
allow for vibration.

A separate regulator is
recommended to control the air
pressure. Air pressure from the
tank is usually to high for
individual air driven tools.