Wiring, Connection diagram – Toa N-8010EX Manuel d'utilisation

Page 14

Advertising
background image

14

8. WIrIng

8.1. connection Diagram

Both upper and lower terminals

(clip terminals) are internally connected.

E-7000TB Terminal board

Station

Mini-clamp connector

232D-02S1B-DA5 (DDK)

(accessory)

Lines should be twisted

N-8000EX/8010EX Exchange

To AC mains or a UPS

(Uninterruptible power supply system)*

If there is a danger of lightning

strikes, insert an appropriate power

gap arrester into the power line.

16 lines

Note

Be sure to ground.

* Select an appropriate UPS taking into consideration the total power consumption of all system components

and the required backup time, and also the requirement that the UPS should employ the on-line power system.

reference

Exchange: Maximum 50 W.

8-Port 10M/100M Switching Hub: 10 W (Differs depending on products.)

note

Once the station line connected between a station and the

exchange is short-circuited or a ground fault occurs on the

cable, power cannot be supplied to the station even when

the short or ground fault is removed.

To restore the situation, be sure to disconnect the cable

connector at the station or exchange, and then connect it

again after several seconds.