Connection diagram – Toa N-8000DI Manuel d'utilisation

Page 10

Advertising
background image

10

6.3. connection Diagram

[General description of connection]

For cables, refer to p. 9.
1. Power supply connection

Connect the supplied power supply cord to AC

Mains or a UPS (Uninterruptible power supply).

About power supply cord handling

The supplied power supply cord is designed for

exclusive use with the N-8000DI.

Use the supplied power supply cord only with the

N-8000DI.

2. contact input terminal connection

(Refer to p. 9, "Removable terminal plug connection.")

[Specification of no-voltage make contact input]

Short-circuit current: 5 mA

Open-circuit voltage: 24 V

* Select an appropriate UPS taking into consideration the total power consumption of all system components

and the required backup time, and also the requirement that the UPS should employ the on-line power

system.

reference

Direct select unit: 16 W (rated) for CE version, 16 W (rated) for CU version

8-Port 10M/100M Switching Hub: 10 W (Differs depending on products.)

Note

Please keep the terminal plug of the attachment not used importantly in preparation for increasing the system.

1

2

2

2

2

Contact input signals

Contact input signals

Contact input signals

Contact input signals

N-8000DI Direct select unit

Be sure to ground.

To AC mains or a UPS

(Uninterruptible power supply system)*.

Note

If there is a danger of lightning strikes,

insert an appropriate surge arrester

into the power line.

10P removable terminal plug

(supplied with the N-8000DI)

Advertising