Type of cable, Removable terminal plug connection, O p. 14 – Toa N-8000AF Manuel d'utilisation

Page 14

Advertising
background image

14

6.3. Removable terminal plug connection

Step 1. Strip a cable jacket of approx. 7 mm to expose inner cable.

Step 2. Loosen the terminal screws and insert the cables.

Step 3. Tighten the terminal screws securely.

Notes

• Tug lightly on the cable to be sure that it does not pull free. If the cable pulls free, loosen the terminal

screw again and reconnect from Step 2.

• Use the screwdriver appropriate to the screws tightened into the terminal plug.

7 mm

For cables, refer to "Type of Cable" above.
Note

Do not solder plate on exposed inner cables when using a stranded wire.

6.2. Type of Cable

The types of cables are to be determined according to the following conditions.

• UTP category 5 Straight through cables with RJ45 connector are to be used for connecting to IP network.

• The number of cables pairs laid should be determined considering the possibility of future expansion of the

system.

• Outdoor wires should be used where wiring passes through inaccessible areas such as ceilings or under

floors where the maintenance is not performed. Indoor wires may also be used, however, in case where there

is no risk of deterioration due to exposure to heat, etc.

Note

Specifications related to junction are as follows.

Removable terminal plug (N-8000AF Control I/O and Audio I/O and Time sync input terminal)

Conductor diameter: ø 0.5 – 2 mm (AWG12 – 24), Solid wire/Stranded wire

Step 4. Insert the wired terminal plug into the terminal block of the N-8000AF.

Removable terminal block

Removable terminal plug

(accessory)

Tighten

N-8000AF rear panel

2

3

4

Advertising