Cooling Operation (1 or 2-Stage Operation)

1. Set the thermostat system mode to COOL and the

thermostat fan mode to AUTO. See Figure 1.

2. Set the thermostat temperature selector to the desired

temperature level. The outdoor fan, compressor, and
indoor blower will all cycle on and off to maintain the
indoor temperature at the desired cooling level. On 2
stage cooling models, the second stage compressor
will cycle as required.

NOTE: If the temperature level is re-adjusted, or the
system mode is reset, the fan and compressor in the
outdoor unit may not start immediately. A protective
timer circuit holds the compressor and the outdoor fan
off for approximately 5 minutes following a previous
operation or the interruption of the main electrical
power.

Heating Operation (2 Stage)

1. Set the thermostat system mode to Heat and the

thermostat fan mode to AUTO. See Figure 1.

2. Set the thermostat temperature selector to the

desired temperature level. The indoor blower and
gas heat module will cycle on and off to maintain
the indoor temperature at the desired heating level.
NOTE: On some units there is a factory set 3 minute
time delay between Stage 1 and Stage 2 heat when
Stage 2 heating is required. See Unit wiring diagram
label.

WARNING:

If overheating occurs, or the gas supply fails to
shut off, shut off the gas valve to the unit before
shutting off the electrical supply.

NOTE: This unit is equipped with a manual-reset fl ame
roll-out limit switch. This switch acts to verify that the
burner fl ame is being drawn into the heat exchanger
tubes. If the fl ame is not being drawn into the tubes, the
fl ame roll-out switch will open within several seconds.
When this switch opens, the gas valve will de-energize
to stop the fl ow of gas. The combustion inducer will stay

energized and continue to operate until the thermostat
is satisfi ed or the switch is closed. Do not reset the fl ame
roll-out switch before identifying and correcting the fault
condition that caused the switch to open. If the switch
will not reset or continues to open, immediately contact
a qualifi ed serviceman to identify and repair the problem.

System Shutdown

Set the thermostat system mode to OFF and the thermostat
fan mode to AUTO. See Figure 1. NOTE: The system will
not operate, regardless of the thermostat temperature
selector’s setting.

Operating the Indoor Blower Continuously

Set the thermostat fan mode to ON (or CONT on some
thermostat models). See Figure 1.

The indoor blower will start immediately, and will run
continually until the fan switch is reset to AUTO.

The continuous indoor blower operation can be obtained
with the thermostat system switch set in any position,
including OFF. NOTE:

The continuous indoor blower

operation is typically used to circulate the indoor air to
equalize a temperature imbalance due to solar loads,
increased occupancy loads, or mechanical equipment
operation.

SYSTEM MAINTENANCE

CAUTION:

Verify all electrical power to the unit is
disconnected and the gas is shut off before
performing the following recommended
maintenance.

CAUTION:

DO NOT touch any of the internal electrical
components while cleaning the unit.

Proper maintenance is most important to achieve the best
performance from the appliance and should be performed
by a qualifi ed service technician at least once a year.
Follow the maintenance schedule and the instructions
below for years of safe, trouble free operation.

• Do not place combustible materials on or against the

cabinet.

• Do not store gasoline or any other fl ammable vapors

and liquids in the vicinity of the unit.

• Annually inspect the physical support of the unit to

ensure that it is physically sound without sagging,
cracks, gaps, etc., around the base so as to provide a
seal between the support and the base.

Figure 1. Digital Thermostat

Fan

Mode

Temperature

Selector

System

Mode