Installation instructions, Important – Reznor EHA Unit Installation Manual Manuel d'utilisation

Page 2

Advertising
background image

RECESS MOUNTING:

1- Heater must be used with recess box.
2- Never install warm air outlet of heater less than

10 in. (250 mm) from fl oor or adjacent wall.

3- Provide a wall opening as:

Depth : 4 5/16 in. (109 mm)

Height : 19 7/8 in. (506 mm)

Length : - Single unit : 14 7/16 in. (368 mm)

- Double unit : 30 3/16 in. (767 mm)

- Triple unit : 46 5/8 in. (1185 mm)

4- Remove the appropriate knock-out from the recess box

for the electrical supply.

5- Attach fi rmly the recess box using provided screws.

Make sure that the edge on each side of the recess box

lean on the drywall and not on the structural parts of the

wall. See marking on the sides of the recess box.

6- Install the heater to the recess box and be sure that the

heater is attach fi rmly with four (4) provided screws.

7- Connect the heater leads to the supply leads according

to national and local codes. See wiring diagram in the

heater.

8- Make sure the fan rotates freely and that there is no

foreign object in the heater.

9- Install the front cover using the provided screws.

IMPORTANT: Make sure that the part of the front cover

without louver is at the top to insure proper air fl ow.

10- To test the heater temporarily, set thermostat at

maximum temperature.

IMPORTANT

1- Do not obstruct front of heater

for at least 48 in. (1220 mm).

2- Any remote thermostat or relay must be connected

to the heater control terminal block.

3- Do not interrupt power supply to control this heater.

CAUTION:

High temperature, risk of fi re, keep electrical cords, drapery,
furnishings, and other combustibles at least 36 in. (915 mm)
from the front of the heater. To reduce the risk of fi re, do not
store or use gasoline or other fl ammable vapors and liquids in
the vicinity of the heater.

SURFACE MOUNTING:

Model 4 in. (102 mm)

1- The surface box must be used with recess box.
2- Never install warm air outlet of heater less than

10 in. (250 mm) from fl oor or adjacent wall.

3- Locate the power supply leads behind the planned location

of the heater (surface box).

4- Mount the surface box securely to the wall with provided

screws.

See illustration to install properly.

5- Follow instructions 4 to 10 as above for recess mounting.

SEMI-RECESSED MOUNTING:

Model 1 in. (25 mm) and Model 2 in. (51 mm)

1- The surface box must be used with recess box.
2- Never install warm air outlet of heater less than

10 in. (250 mm) from fl oor or adjacent wall.

3- Provide a wall opening as:

Depth for 1 in. model : 3 5/16 in. (84 mm)

Depth for 2 in. model : 2 5/16 in. (59 mm)

Height : 19 7/8 in. (506 mm)

Length : - Single unit : 14 7/16 in. (368 mm)

- Double unit : 30 3/16 in. (767 mm)

- Triple unit : 46 5/8 in. (1185 mm)

4- Mount the surface box securely to the wall with provided

screws.

See illustration to install properly.

5- Follow instructions 4 to 10 as above for recess mounting.

Surface mounting and
Semi-recessed mounting
Single unit

Surface mounting and
Semi-recessed mounting
Triple unit

Surface mounting and
Semi-recessed mounting
Double unit

INSTALLATION INSTRUCTIONS