To open the door manually, Care of your opener – Chamberlain 547445 Manuel d'utilisation

Page 34

Advertising
background image

34

Care of Your Opener

MAINTENANCE SCHEDULE

Every Month

• Manually operate door. If it is unbalanced or binding,

call a trained door systems technician.

• Check to be sure door opens & closes fully. Adjust

limits and/or force if necessary (See pages 28 and 29).

• Repeat the safety reverse test. Make any necessary

adjustments (See Adjustment Step 3).

Every Year

• Oil door rollers, bearings and hinges. The opener does

not require additional lubrication. Do not grease the
door tracks.

DISCONNECT THE TROLLEY:

The door should be fully
closed if possible. Pull
down on the emergency
release handle (so that the
trolley release arm snaps
into a vertical position) and
lift the door manually. The
lockout feature prevents the
trolley from reconnecting
automatically, and the door
can be raised and lowered
manually as often as
necessary.

TO RE-CONNECT THE
TROLLEY:

Pull the emergency release
handle toward the opener at
an angle so that the trolley
release arm is horizontal. The
trolley will reconnect on the
next UP or DOWN operation,
either manually or by using
the door control or remote.

To Open the Door Manually

THE REMOTE CONTROL BATTERY

To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.
To reduce risk of fi re, explosion or chemical burn:
• Replace ONLY with 3V2032 coin batteries.
• DO NOT recharge, disassemble, heat above 100° C

(212° F) or incinerate.

The lithium battery should produce power for up to
5 years.

To replace battery, use the visor
clip or screwdriver blade to pry
open the case as shown. Insert
battery positive side up (+).

Dispose of old battery properly.

Replace the battery with ONLY
3V2032 coin cell batteries.

NOTICE: To comply with FCC and or Industry Canada rules (IC),
adjustment or modifi cations of this receiver and/or transmitter are
prohibited, except for changing the code setting or replacing the
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards for Home or offi ce use.
Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.

Battery
positive
side up (+)

To prevent possible SERIOUS INJURY or DEATH from
a falling garage door:
• If possible, use emergency release handle to

disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced
door could result in an open door falling rapidly and/
or unexpectedly.

• NEVER use emergency release handle unless garage

doorway is clear of persons and obstructions.

• NEVER use handle to pull door open or closed. If

rope knot becomes untied, you could fall.

To reconnect

Emergency
Release Handle
(Down and Back)

Trolley
Release
Arm

Trolley

Lockout position
(Manual disconnect)

Trolley
Release Arm
(In Manual
Disconnect
Position)

Trolley