Tjernlund RT1500 Rooftop Draft Inducer 8504160 Rev 12/09 Manuel d'utilisation
Page 2

TABLE OF CONTENTS
PAGE(S)
DESCRIPTION ............................................................................................................................................................. 1
DIMENSIONS AND SPECIFICATIONS ........................................................................................................................ 1
FAN PERFORMANCE CURVES.....................................................................................................................................2
INSTALLATION RESTRICTIONS & CAUTIONS ........................................................................................................... 3
INSTALLER RESTRICTIONS & CAUTIONS IN FRENCH CANADIAN ..................................................................... 3-4
TERMINATION CLEARANCES FOR CANADIAN & U.S. INSTALLATIONS ................................................................. 4
INSTALLATION .......................................................................................................................................................... 5-7
RT750 / RT1500 - PSA-1 FAN PROVING SWITCH INSTALLATION .......................................................................... 7
WIRING .......................................................................................................................................................................8-9
RT750 / RT1500 - PSA-1 SAFETY INTERLOCK AND DRAFT ADJUSTMENT SET-UP PROCEDURE ................9-10
RT750H / RT1500H SPEED CONTROL ADJUSTMENT ............................................................................................ 10
COMBUSTION AIR ......................................................................................................................................................10
INSPECTION & MAINTENANCE .................................................................................................................................10
TROUBLESHOOTING ............................................................................................................................................10-11
HOW TO OBTAIN SERVICE & LIMITED WARRANTY ................................................................................................11
REPLACEMENT PARTS ..............................................................................................................................................11
Tjernlund Products welcomes your comments and questions. Call us at 800-255-4208, Fax 651-426-9547, Email us at
[email protected] or write to: Customer Service, Tjernlund Products, Inc., 1601 Ninth Street, White Bear Lake, MN 55110-6794.
DESCRIPTION
RT750 & RT1500 models are supplied with the model PSA-1 Fan Proving Switch which will disable the burner(s) if an Inducer mal-
function should occur and are compatible with Tjernlund UC1 and UCRT interlock controls. The RT750H & RT1500H are supplied with
a wall mount speed control to vary inducer performance in solid fuel applications. The Rooftop Inducer may be used on positive or
negative pressure rated chimneys because the fan creates a negative pressure throughout the entire venting system. Suitable for use
on natural gas, LP-gas, oil-fired, solid fuel heating systems or general ventilation. Also applicable for dryers, gas fireplaces, stoves,
BBQ’s or pizza ovens. The Rooftop Inducer must always be installed outdoors at the vent system termination. Refer to heating appli-
ance manufacturer's instructions regarding specific venting requirements.
GENERAL SELECTION INFORMATION
Selection of a Rooftop Inducer involves determination of the maximum volume of air or gases to be handled, their density and the
maximum static pressure which the fan must overcome. Rooftop Inducer performance needs to be de-rated from 70
O
F performance
curves to anticipated air or gas temperatures. Please feel free to contact us for application and model selection assistance by calling
800-255-4208 or email us at [email protected]. Vent layout or other information can be faxed to 651-426-9547.
DIMENSIONS AND SPECIFICATIONS
1
.373
.063
kW
lbs
kgs
in
in
mm
in
mm
in
mm
in
mm
mm
E
D
Weight
Dimensions
C
B
A
11 15/16
7 15/16
14 1/2
368
201
17
432
303
8
16
406
203
34
15.42
16 3/4
425
18 1/2
470
286
11 1/4
21.32
552
21 3/4
47
hp
MODEL
Voltage
RPM
Amps
Power Rating
120 VAC
1.2
1/12
1550
RT750H
RT750
120 VAC
5.8
1/2
1550
RT1500H
RT1500
F
mm
in
22 1/2
572
445
17 1/2
( )
inlet
D
E
F
B
C
A