8
WIRING
INSTALLING ELECTRICAL WHIP
Remove the (2) 8-32 nuts holding coverplate and gasket on the electrical access of the Inducer.
Pull the wires out of the Inducer and wire nut them to the electrical leads from the whip referenc-
ing appropriate diagram below. Carefully stuff the wired connections back into the Inducer and
secure coverplate and gasket to Inducer housing using the nuts removed from above. Firmly
tighten until gasket compresses, (See Diagram Q).
Secure box on opposite end of whip to power supply conduit and wire in accordance to the
diagram appropriate for installation. Place provided gasket between cover and box firmly tighten.
All wiring from the Rooftop Inducer to the appliance must be in compliance with local codes or in their absence, the National Electric
Code (NFPA 70).
All wiring from the Rooftop Inducer to the appliance must be appropriate class 1 wiring as follows: Installed in rigid metal conduit,
intermediate metal conduit, rigid non-metallic conduit, electrical metallic tubing, Type MI Cable or be otherwise suitably protected from
physical damage.
MOTOR
CAPACITOR
GND
L1
MTR
N
WHITE
BLACK
RED
ORANGE
BROWN
MTR
NEUT
WHT / RED
COOLING FAN
THERMOSTAT
INDUCER
MOTOR
THERMOSTAT
WHT
/ RED
BL
ACK
BRO
W
N
OR
AN
GE
BRO
W
N
RED
NUTS
OR
AN
GE
BL
ACK
RED
WHT
/ RED
WHI
TE
WHI
TE
BLUE
BLUE
BLACK
PRE-WIRED 4 FT. WHIP
INCLUDED
INCLUDED 4 X 4 BOX
CUTAWAY SIDE VIEW
IMPELLER
WI
RE
BLACK
VAC
115
FIGURE 8052071 3-3-11
ROOFTOP INDUCER ELECTRICAL WHIP CONNECTIONS
DIAGRAM Q