Dell PowerEdge C6220 II Manuel d'utilisation

Page 152

Advertising
background image

152

|

Utilisation du programme de configuration du système


Tableau 2-2. Tableau des commandes IPMI

Nom

NetFn

Code

IPMI2.0 BMC

Commandes globales de périphérique IPMI

Get Device ID

App (0x06)

0x01

M

Y

Broadcast Get Device ID

App (0x06)

0x01

M

Y

Cold Reset

App (0x06)

0x02

O

Y

Warm Reset

App (0x06)

0x03

O

Get Self Test Results

App (0x06)

0x04

M

Y

Manufacturing Test On

App (0x06)

0x05

O

Y

Set ACPI Power State

App (0x06)

0x06

O

Y

Get ACPI Power State

App (0x06)

0x07

O

Y

Get Device GUID

App (0x06)

0x08

O

Y

Get NetFn Support

App (0x06)

0x09

O

Y

Get Command Support

App (0x06)

0x0A

O

Y

Get Command Sub-function Support

App (0x06)

0x0B

O

Y

Get Configurable Commands

App (0x06)

0x0C

O

Y

Get Configurable Command Sub-
functions

App (0x06)

0x0D

O

Y

Set Command Enables

App (0x06)

0x60

O

Y

Get Command Enables

App (0x06)

0x61

O

Y

Set Command Sub-function Enables

App (0x06)

0x62

O

Y

Get Command Sub-function Enables

App (0x06)

0x63

O

Y

Get OEM NetFn IANA Support

App (0x06)

0x64

O

Y

Commandes de minuteur de surveillance BMC

Reset Watchdog Timer

App (0x06)

0x22

M

Y

Set Watchdog Timer

App (0x06)

0x24

M

Y

Get Watchdog Timer

App (0x06)

0x25

M

Y

Commandes de périphérique et de messagerie BMC

Set BMC Global Enables

App (0x06)

0x2E

M

Y

Get BMC Global Enables

App (0x06)

0x2F

M

Y

Clear Message Flags

App (0x06)

0x30

M

Y

Get Message Flags

App (0x06)

0x31

M

Y

Enable Message Channel Receive

App (0x06)

0x32

O

Y

Advertising