Cx1 technical data (cont.) – CCI Thermal Technologies CX1 - ProVector Explosion-Proof Convection Heater Manuel d'utilisation
Page 9

– 9 –
CX1 TECHNICAL DATA (cont.)
All units are single phase
* Or equivalent breaker as per local electrical inspection authority requirements.
** For 3.6 kW heaters rated T3 cabinet length is 49.5" (1256 mm). 3.6 kW heaters rated T2A cabinet length is 31.3" (796 mm)
*** Ensure supply wire size adheres to applicable local and national electrical codes
Notes
1. Heater is functioning normally if, at rated voltage, the current draw is within 10% of the value in this table.
2. Operation at lower voltages that rated will result in reduced output and current draw.
Actual Output (kW) = [(Supply Voltage)2 ÷ (Rated Voltage)2] × Rated Unit Wattage (kW)
3. Add suffix "T" for optional built-in thermostat. Thermostat not available on IIB + H2 models.
4. Add suffix "H" for high-temperature ambient storage option. High temperature storage option is not available with thermostat option. Not available on IIB
models.
5. For IIB model with XCT built-in thermostat - Class I, Div. 1 & 2, Groups C & D; Zones 1 & 2, Groups IIA and IIB
6. For IIC model with XT built-in thermostat - Class I, Div. 1 & 2, Groups A,B,C & D; Zones 1 & 2, Groups IIA, IIB, IIC
7. IIC Grouping units come with
x-Max® housing
8. Remote mounted, Defender, explosion-proof room thermostats are not suitable for Group B & IIC applications
9. Remote contactors are required on all 600V heaters, and heaters with a current draw greater than 22 amps
(supplied & installed by others), when utilizing XT-311 remote thermostat.
10. Temperature code ratings: T2A - 536°F (280°C), T3 - 392°F (200°C)
MODEL CODE
kW
(BTU/hr)
UNIT
VOLTAGE
(VOLTS)
BASIC
UNIT
GAS GROUP
SUPPLY
WIRE
SIZE
(AWG)***
UNIT
CURRENT
(AMPS)
MAXIMUM
CIRCUIT
FUSE
(AMPS)*
CABINET
LENGTH
in (mm)
TEMP.
CODE
IIB + H2 IIB
IIC
W/O
T'STAT
W/
T'STAT
W/O
T'STAT
W/
T'STAT
CX1-400160-0528-T2A
5.28
(18016)
400
-
-
10
13.2
15
59.5 (1511)
T2A
CX1-400160-076-T2A
7.6
(25932)
400
-
10
19.0
20
59.5 (1511)
T2A
CX1-415160-009-T3
0.9
(3071)
415
-
-
12
2.2
15
31.3 (796)
T3
CX1-415160-012-T3
1.2
(4095)
415
12
2.9
15
31.3 (796)
T3
CX1-415160-0135-T3
1.35
(4606)
415
-
-
12
3.3
15
31.3 (796)
T3
CX1-415160-018-T3
1.8
(6142)
415
12
4.3
15
31.3 (796)
T3
CX1-415160-0269-T2A
2.69
(9179)
415
-
-
12
6.5
15
31.3 (796)
T2A
CX1-415160-0359-T3
3.59
(12250)
415
-
-
12
8.7
15
49.5 (1256)
T3
CX1-415160-036-T3**
3.6
(12284)
415
12
8.7
15
49.5 (1256)
T3
CX1-415160-048-T2A
4.8
(16378)
415
12
11.6
15
49.5 (1256)
T2A
CX1-415160-0568-T2A
5.68
(19381)
415
-
-
10
13.7
15
59.5 (1511)
T2A
CX1-415160-076-T2A
7.6
(25932)
415
-
10
18.3
20
59.5 (1511)
T2A
CX1-480160-012-T3
1.2
(4095)
480
12
2.5
15
31.3 (796)
T3
CX1-480160-018-T3
1.8
(6142)
480
12
3.8
15
31.3 (796)
T3
CX1-480160-036-T3**
3.6
(12284)
480
12
7.5
15
49.5 (1256)
T3
CX1-480160-048-T2A
4.8
(16378)
480
12
10.0
15
49.5 (1256)
T2A
CX1-480160-076-T2A
7.6
(25932)
480
-
10
15.8
20
59.5 (1511)
T2A
CX1-600160-012-T3
1.2
(4095)
600
-
12
2.0
15
31.3 (796)
T3
CX1-600160-018-T3
1.8
(6142)
600
-
12
3.0
15
31.3 (796)
T3
CX1-600160-036-T3**
3.6
(12284)
600
-
12
6.0
15
49.5 (1256)
T3
CX1-600160-048-T2A
4.8
(16378)
600
-
12
8.0
15
49.5 (1256)
T2A
CX1-600160-076-T2A
7.6
(25932)
600
-
12
12.7
15
59.5 (1511)
T2A