Annexe 3: schéma de système, Annexe a-4 – Tweco 38 (CE) CutMaster Manuel d'utilisation

Page 46

Advertising
background image

Annexe

A-4

ANNEXE 3: SCHÉMA de SYSTÈME

1

1

2

2

3

3

4

4

A

B

C

D

E

F

AC

3

CURRENT
CONTROL

1

2

1

MAIN PCB ASSEMBLY

1

2

J5

2

1

P5

GAS

1

3

DC

FAN1

1
2

P4

TEMP

J4

2

2

M1

CURRENT ADJUST
20 - 30

RED

BLACK

19X1773

TS1

OVER-TEMP

FILTE

RING

PFC INDUCTOR

T1

BIAS
CONVERTER

LOGIC AND CONTROL

CIRCUITRY

PS1

PRESSURE SW

3

1

P6

3

1

J6

2

2

CW

P9

J9

D13

D16

D19

D7

SW2

RUN

SET

1

2

J2

3

2

3

1

P2

BR2

PANEL INDICATOR

(5)

(6)

(7)

(8)

(9)

(10)

(11)

ZERO

1

4

J7

TEST

K1

12VDC

+

NORMALLY CLOSED

TEST POINTS:

TP1 LOGIC COMMON

TP2 SHORT TO TP23 TO DISABLE BIAS SUPPLY

TP6 SHORT TO TP24 TO DISABLE POWER

FACTOR CORRECTION

TP8 SHORT TO TP26 TO DISABLE SHORTED

TORCH PROTECTION

(E14A)

(E16A)

(E15A)

(E12A)

(E16B)

(E12B)

(E14B)

(E15B)

1

2

3

4

2

3

BR1

4

1

E16A

Q8

-+

E14A

E15A

E12B

E13

E16B

E1

STUD

Q7

E11

-+

E15B

E2

D47

E14B

E12A

E18

A-03405

CAUTION: SOME PORTIONS OF THE CONTROL/

LOGIC CIRCUITRY ARE CONNECTED TO THE

INPUT LINE. CONNECTION TO A GROUNDED

INSTRUMENT COULD CAUSE A SHOCK

HAZARD OR DESTROY THE POWER SUPPLY.

ACCESS BY AN AUTHORIZED TECHNICIAN ONLY.

SW1

(E1)

SW1

120/208/230V

INPUT

50/60HZ

(E2)

L1

INPUT 230V ONLY

CHASSIS GND

EMC

FILTER
CE ONLY

Advertising