Summit SCR1400W Manuel d'utilisation

Page 14

Advertising
background image

14

Display shows
“E1” or “E2”.

• The air temperature sensor has failed.

• Call for service.

The alarm
sounds and
the
temperature
display
flashes.

• Has the appliance door been open for

longer than 60 seconds? If not, then the
temperature has risen higher or fallen
lower than the temperature that has
been set. This could be due to:

The appliance door being opened too
often.

The ventilation opening being
covered or too dusty.

A lengthy interruption to the power
supply.

A large number of bottles recently
added to the unit.

• If yes, close the door.




• Do not open the door more often than

necessary.

• Clear the obstructions and clean off

the dust.

• Leave the appliance to work for a

while until the set temperature has
been reached.

The icon “--” is
lit up and
flashing in the
temperature
display.

• The display temperature is out of range. • Only temperatures within the range

0~99°F/-9~37°C can be displayed. If
the interior temperature is not within
this range, the icon “--” will be
displayed instead. That is normal.


Advertising