HANDLE INSTALLATION AND DOOR ALIGNMENT
For the door to close properly, it is necessary to maintain a
minimum space of
9
⁄
32
” (7mm) between the door and cabi-
net flange (See Figure 6). This space can be adjusted by
adjusting the top and bottom hinge adapter brackets.
NOTE
Door Alignment Procedure
The door should be parallel to the sides and top of the ap-
pliance. If alignment is necessary the door may be adjusted
by loosening the 2 screws which secure the hinge adapter
brackets on the top and bottom of the door and adjusting
the door side to side. Use a
5
⁄
32
” allen wrench for this pro-
cedure. (See Figure 6 below). When finished aligning the
door, tighten the screws securely.
Handle Installation (Solid Door Models)
1. Remove the handle, (2) screws, and
5
⁄
32
” allen wrench
from the bag shipped inside the cabinet.
2. Locate handle opposite the hinges and secure in place
using the (2) screws and the allen wrench.
(See Figure 5).
Screws
Handle
Figure 5
Right hand hinged
door shown
Figure 6
Hinge adapter bracket
located on the top and bot-
tom of the door.
Remove top
hinge pin to re-
move the door.
Door should be
parallel to top
and sides of
appliance.
9
⁄
32
”
(7.1mm)