10. Attach “appliance Supply Cable” to the 3 or 5 pole

terminal block & ground terminal located rear knockout
in wiring compartment.

“IMPORTANT”. Individual wires of the “appliance Supply
Cable” MUST connected to same number terminals that
correspond to the numbered circuit breaker (branch circuit)
terminals located in the F.W.T. box (per 7 above).

11. Recheck for proper wiring connections following wiring

diagram.

12. Replace front control panel and F.W.T. box cover and

secure with fasteners.

Upon completion of power input supply connection test
fryer for operation by following the procedure as described
in the section “Proper Method of Filling Fryer Tank”.

Counter Top/Modular Models – Rated Less
Than 48 Amperes

1. Open front cover of the field wiring compartment by

removing fasteners. The field wiring compartment is
located lower front on 36ES21 models and at rear on
36ES11, E24 (remove tank for front access).

INSTALLATION Continued

2. Feed input power supply through rear snap connector

and/or through knockout into field wiring.

3. Attach input power cable leads to the terminal block,

either single or three phase arrangement, as required
according to wiring diagram.

4. Close field wiring compartment cover by replacing

fasteners (replace tank if required).

Upon completion of power input supply connection test
fryer for operation by following the procedure as described
in the section “Proper Method of Filling Fryer Tank”.

Ventilation

Proper ventilation is required for the safe removal of grease
laden air generated during the frying process. Local and/or
National codes dictate the type of ventilating system to
be used with this appliance. Care should be taken in the
positioning of the ventilating system to prevent grease from
dripping from the hood into the fryer.

Preparation Before Use

After the fryer has been properly installed and checked for
operation, it will be necessary to clean the protective coating
from the fry tank as follows:

1. Have power to the fryer turned “OFF” at the service

disconnect box.

2. Remove baskets from the fry tank.

3. If applicable, remove the automatic basket lift holders by

lifting them off the raising rods. These are right and left
basket holders. Note the position for replacement.

OPERATION

4. Lift the element handle until the heating elements are in

full raised position.

5. Lift the tank out of the fryer for cleaning. If a special fry

tank cleaner is used, carefully follow the manufacturer’s
instructions for its use. Ammonia, vinegar solution or
baking soda solution may be used for cleaning the tank.
Rinse tank thoroughly with clean, hot water and dry
completely.

6. Replace the tank in the fryer. If the tank has the optional

drain valve, make sure that this valve is tightly closed.