Installation instructions, Tools and parts, Location requirements – Whirlpool MKC2150AS Manuel d'utilisation

Page 2: Required cutout dimensions, Trim kit frame dimensions

Advertising
background image

2

INSTALLATION INSTRUCTIONS

Tools and Parts

Tools Needed

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.

Parts Supplied (not shown to scale

Location Requirements

The microwave oven may be installed over a built-in oven. If
installing over a built-in oven, make sure there is a minimum of 3"
(7.6 cm) between the top of the lower oven cutout and the
microwave oven cutout floor.
The microwave oven may also be installed in a cabinet by itself
(without a built-in oven below). For best usability, we recommend
a minimum distance of 36" (91.4 cm) from the floor to the cutout
floor.
Make sure the surrounding cabinetry has clearance to open and
close freely. Allow a clearance of at least 1

⁹⁄₁₆" (4.0 cm) below the

cutout floor (3" [7.6 cm] for installation above a built-in oven), and
a clearance of at least 2" (5.1 cm) above the cutout opening.

Required Cutout Dimensions

NOTES:

Depth requirements depend upon receptacle and its location
within or outside of recommended region. See illustration and
chart above.

Height dimension is critical: 17" (43.2 cm) minimum, 17

¹⁄₈"

(43.5 cm) maximum.

Width measurement has ±1/16" (2 mm) tolerance.

3" (7.6 cm) minimum dimension is from lower oven cutout
ceiling to microwave oven cutout floor.

Trim kit frame extends 1

¹⁄₁₆" (2.7 cm) above and below the

cutout opening.

Trim Kit Frame Dimensions

*27" (68.6 cm) trim kit

**30" (76.2 cm) trim kit

Measuring tape

Pencil

Phillips screwdriver

Drill

7/64" drill bit

Rear duct

Bottom duct

Rails (2)

Short screws (19)

(16 + 3 extra)

Long wood screws

(6 - painted) (4 + 2 extra)

Trim kit frame

A. Upper cabinet
B. Microwave oven cutout

C. Lower oven cutout

D. Lower cabinets

E. Floor

3"

(7.6 cm)

B

B

D

36"

(91.4 cm)

C

2"

(5.1 cm)

2"

(5.1 cm)

1

⁹⁄₁₆

"

(4.0 cm)

A

E

A. Trim kit frame overhang
B. Cutout for lower oven

C. Recommended region for receptacle

location (no less than 7" [17.8 cm] to
the right of cutout centerline)

D. Cutout centerline

Receptacle Location

Minimum Depth

Within recommended
region

20" (50.8 cm) with flush receptacle;
22" (55.9 cm) with non-flush receptacle

Outside recommended
region

22" (55.9 cm) with flush receptacle;
24" (61.0 cm) with non-flush receptacle

3"

(7.6 cm

)

7"

(17.8 cm)

A

1

¹⁄₁₆

"

(2.7 cm)

1

¹⁄₁₆

"

(2.7 cm)

B

C

D

23

¹⁄₈

" (58.7 cm)

17

¹⁄₈

" (43.5 cm)

max.

17" (43.2 cm)

min.

For minimum depth requirements, see chart.

26

⁷⁄₈

" (68.2 cm)*

*

29

³⁄₄

" (75.6 cm)**

2

¹⁄₁₆

" (5.2 cm)*

*

3¹⁄₂

" (8.9 cm)**

22

³⁄₄

" (57.8 cm)

12

¹⁄₄

"

(31.1 cm

)

1

³⁄₁₆

" (3.0 cm)

19

¹⁄₈

"

(48.6 cm)

3⁷⁄₁₆

"

(8.7 cm)

Advertising