Installation requirements, Tools and parts, Location requirements – Whirlpool GXW7330DXS Manuel d'utilisation

Page 4

Advertising
background image

4

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.

Tools needed

Level

Drill with 1¼" (3.0 cm),

³⁄₈" (9.5 mm), and ⁵⁄₁₆" (7.9 mm)

drill bits

Pencil

Wire stripper or utility knife

Tape measure or ruler

Pliers

Caulking gun and weatherproof caulking compound

Vent clamps

Jigsaw or keyhole saw

Flat-blade screwdriver

Metal snips

Phillips screwdriver

Metric hex key set

Parts needed

Home power supply cable

½" (12.7 mm) UL listed or CSA approved strain relief

3 UL listed wire connectors

For vented installations, you will also need:

1 wall or roof cap

Metal vent system

For non-vented (recirculating) installations, you will also
need:

Recirculation Kit Part Number W10349327 for non-vented
(recirculating) installations only. See “Assistance or Service”
section to order.

6" (15.2 cm) dia. round metal vent duct - length required is
determined by ceiling height.

Parts supplied

Remove parts from packages. Check that all parts are included.

Hood canopy assembly with ventilator and light bulbs
installed

Vent transition with back draft dampers installed

Metal grease filter(s)

Vent cover support bracket

Mounting template

2-piece vent cover

2 - 3.5 x 9.5 mm screws

2 - 2.9 x 6.5 mm screws

6 - 5 x 45 mm mounting screws

2 - 8 x 40 mm wall anchors

4 - 10 x 50 mm wall anchors

T20 Torx

®

adapter

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located behind the left filter on the rear wall of the vent
hood.

Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.

Grounded electrical outlet is required. See “Electrical
Requirements” section.

The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) Installation see “For Non-
vented (recirculating) Installations Only” in “Connect Vent
System” section. Recirculation Kit Part Number W10349327 is
available from your dealer or an authorized parts distributor.

NOTE: This product will not comply with Energy Star
specifications when installed as non-vented (recirculating) with
the optional recirculation kit.

All openings in ceiling and wall where canopy hood will be
installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.

Product Dimensions

*For non-vented (recirculating) installations

**For vented installations

®†TORX is a registered trademark of Saturn Fasteners, Inc.

30" (76.2 cm) or

36" (91.4 cm)

10"

(25.4 cm)

20" (50.8 cm)

14

¹⁄₈"

(35.9 cm)

7

¹⁄₄"

(18.3 cm)

8

¹⁄₈"

(20.7 cm)

*28

⁷⁄₈" (72.6 cm) min.

42

¹⁄₁₆" (106.9 cm) max.

**28

³⁄₈" (72.0 cm) min.

38" (96.6 cm) max.

1

¹ ₂" (4.0 cm)

Advertising
Ce manuel est liée aux produits suivants: