Whirlpool WFG505M0BS Manuel d'utilisation

Page 13

Advertising
background image

13

To Convert Gas Pressure Regulator

1. Open broiler door and remove broiler rack. The gas pressure

regulator is located in the back right hand corner of the broiler
compartment.

IMPORTANT: Do not remove the gas pressure regulator.

NOTE: Do not remove the spring beneath the cap.

2. Remove the cap from the gas pressure regulator using a

flat-blade screwdriver.

NOTE: Be sure sealing washer remains in the same position.

3. To convert to LP gas, unscrew the plastic adjustment screw

by hand, turn it over, and screw it in again.

4. Reinstall the cap.

To Convert Surface Burners

1. Remove burner grate, burner caps and burners.

2. Locate LP gas orifice spuds for top burners in the bag

containing literature included with the range. Two LP gas
spuds are stamped “88 (Yellow/Black),” two are stamped
“116 (Yellow/Orange),” and one is stamped “70 (Yellow/
White).”

3. Remove Natural gas orifice spuds using a 7 mm (

⁹⁄₃₂")

combination wrench.

4. Install LP gas orifice spuds using a 7 mm (

⁹⁄₃₂") combination

wrench.

A. Gas pressure regulator

A. Cap

Inlet pressure
to Natural gas

Inlet pressure
to LP gas

A. Cap
B. Sealing washer

C. Adjustment screw

A

A

A

C

B

180º

A. Burner cap
B. Burner

C. Center burner

A. Spud
B. Holder

A

B

C

A

B

Advertising