INSTALLATION INSTRUCTIONS

Prepare Built-In Microwave/Oven

Combination

1. Decide on the final location for the oven. Locate existing

wiring to avoid drilling into or severing wiring during
installation.

2. To avoid floor damage, set the oven onto cardboard prior to

installation. Do not use handle or any portion of the front
frame for lifting.

3. Remove the shipping materials and tape from the oven.

4. Remove the hardware package from inside the bag

containing literature.

5. Remove and set aside racks and other parts from inside the

oven.

6. Move oven and cardboard close to the oven’s final location.

Remove Oven Door

IMPORTANT: Use both hands to remove oven door(s).

1. Open the oven door.

2. Locate the oven door latches in both corners of the oven

door, and rotate the latches forward to the unlocked position.

3. Grasp the edges of the oven door with both hands and close

the oven door until it will no longer close. Lift and pull oven
door toward you and remove. Set the oven door aside on a
covered work surface.

Make Electrical Connection

IMPORTANT: For model KEHU309B, you must use 6 gauge
copper or 4 gauge aluminum wire.

This oven is manufactured with a neutral (white) power supply
wire and a cabinet-connected green (or bare) ground wire twisted
together.

1. Disconnect power.

2. Feed the flexible conduit from the oven through the opening

in the cabinet.

3. Remove junction box cover, if it is present.

4. Install a UL listed or CSA approved conduit connector to the

junction box.

5. Route the flexible conduit from the oven to the junction box

through a UL listed or CSA approved conduit connector.

6. Tighten screws on conduit connector.

7. See “Electrical Connection Options Chart” to complete

installation for your type of electrical connection.

A. Oven door latch in locked

position

B. Oven door latch in unlocked

position

WARNING

Excessive Weight Hazard

Use two or more people to move and install oven.

Failure to do so can result in back or other injury.

A

B

A. UL listed or CSA approved conduit connector

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge solid copper wire.

Electrically ground oven.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 6 gauge copper or 4 gauge aluminum wire.

Electrically ground oven.

Failure to follow these instructions can result in death,
fire, or electrical shock.