13

Owner’s manual: model 92000 portable outdoor heater 12/3/03

®

Contact 1-800-762-1142 for assistance.

Do not return to place of purchase.

14

Owner’s manual: model 92000 portable outdoor heater 12/3/03

Troubleshooting

If the problem is:

And this condition exists:

Then do this

Burner won’t light

Gas pressure is low
Blockage in burner openings
Blockage in venturi tube
Blockage in gas line
Control knob is not in ON position

Replace bottle/cylinder or canister
Clear blockage
Clean venturi
Check gas line for blockage
Turn control knob to ON

Burner won’t stay lit

Bad thermocouple
Corrosion at thermocouple
Burner flame not touching
thermocouple

Replace ODS
Clean contact
Contact certified technican

Burner flame is low

Note: Heater operates at reduced
efficiency below 40ºF (5ºC)

Gas pressure is low

Outdoor temperature is less than 40ºF
and tank is less than 1/4 full
Control knob fully ON

Turn Control Knob OFF and replace
bottle/cylinder or canister
Use a full bottle/cylinder or canister

Check burner and all openings for
blockage

Emitter glows uneven

Gas pressure is low
Heater not level
Burner tilted

Replace bottle/cylinder or canister
Level heater
Straighten burner

Carbon build-up

Base is not on a level surface
Heater is level
Dirt or film on reflector and emitter

Place heater on a level surface
Clean burner
Clean reflector and emitter

Thick black smoke

Blockage in burner

Remove blockage and clean burner
inside and outside

Advertising