Location Requirements

Select a location with a solid floor. Dryers installed in
residential garages must be elevated 18 inches (46 cm)
above the floor.

No other fuel burning appliance should be installed in
the same closet with the dryer.

The dryer must not be installed or stored in an area
where it will be exposed to water and/or weather.

Leveling legs can be adjusted from inside the dryer
with a 1/4 inch driver. All four legs must rest firmly on
the floor so the weight of the dryer is evenly
distributed. The dryer must not rock.

The dryer needs sufficient clearance and an adequate
air supply for proper operation and ventilation, and for
easier installation and servicing. (Minimum clearances
are shown below.)

Figure 14

D823I

1

Closet Door

3

Outer Wall of Enclosure

2

Centered Air Openings (G) (2 openings minimum)

**NOTE: For new installations, locate top of wall vent 42 inches (106.7 cm) above floor to make venting easier to
connect.

1

2 (G)

3

A

B

A

C

A

D

E

F

F

FRONT VIEW

(w/o Closet Door)

SIDE VIEW

(Closet Door)

FRONT VIEW

(Closet Door)

** 42 in.

(106.7 cm)

Area

Description

Free Standing/Alcove

Installation

Closet Installation

A

Dryer sides and rear clearance

0" (0 cm)

0" (0 cm)

B

Dryer top clearance

12" (30.5 cm)

12" (30.5 cm)

C

Dryer front clearance

Not Applicable

2" (5.1 cm)

D

Exhaust duct clearance to
combustible material

2" (5.1 cm)

2" (5.1 cm)

E

Weather hood to ground clearance

12" (30.5 cm)

12" (30.5 cm)

F

Distance from floor or ceiling to
hole edge

Not Applicable

3" (7.6 cm)

G*

Area of centered air openings in
closet door

Not Applicable

40 sq. in./open (260 sq. cm)

*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)