ENGLISH

Activate the cursor N to release the ven-

tilation grille and at the same time slide

out the grille (in the direction of the arrow)

to free it. The prefilter is located in the air

outlet area under the Hepa filter. Replace

or clean the prefilter by washing it with

water, then dry it and put it carefully back

in place. Refit the HEPA filter and venti-

lation grid, sliding it in until you hear the

cursor click into place.

STARTING THE CARPET BEATER

To work, press the release pedal down

and lower the vacuum cleaner at the same

time. The carpet beater attachment will start

up. Avoid frequent use of the carpet beater

attachment on special rugs or carpets that

could become damaged over time.

CARPET BEATER CONTROL

The carpet beater control device constantly

regulates the operation of the beater:

Green light: the carpet beater is working

correctly.

Red light: the carpet beater is locked or

it has been subjected to excessive stress.

Lift the base with the adjustment device

P, then move the appliance to the upright

position for a few seconds and resume

working. If the red light persists, switch

off the appliance, unplug it and check the

causes of blockage.

Red/Green light: the roller is not touching

the floor. Adjust the height of the base

using the dial P. It is possible that the roller

is worn or the transmission belt is broken.

Replace the roller or transmission belt.