Napoleon Fireplaces Outdoor Torch - GSST8 Manuel d'utilisation
Page 6

6
W415-0689 / C / 06.13.12
RATES AND EFFICIENCIES
NATURAL GAS
PROPANE GAS
Altitude
0 - 4,500*
0 - 4,500*
Maximum Input
6,000
6,000
Minimum Inlet Gas Supply Pressure
4.5” Water Column
11” Water Column
Maximum Inlet Gas Supply Pressure
7” Water Column
13” Water Column
Manifold Pressure Under Flow Conditions
3.5” Water Column
10” Water Column
4.3A
THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER
to
conform with local codes. Installation practices vary from region to region and it is important to know the
specifi cs that apply to your area, for example in Massachusetts State:
•
The appliance off valve must be a “T” handle gas cock.
• The
fl exible connector must not be longer than 36 inches.
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute
® (NFI) as NFI Gas
Specialists
www.nficertified.org
2.3 GENERAL
INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ENSURE ITS OPERATION
AND QUALITY!
When the appliance is installed at elevations above 4,500ft, and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of
4% for each additional 1,000ft.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
Purge all gas lines with the glass door of the appliance removed. Ensure that a continuous gas fl ow is at the
burner before replacing the door.
Objects placed in front of the appliance must be kept a minimum of 48” from the front face of the unit.
Use only authorized accessories designed for and listed with the model.