10.0 TROUBLE
SHOOTING
SYMPTOM
PROBLEM
TEST SOLUTION
No warm air is
coming out of
the appliance
Room temperature
is higher than the
appliance setting (if it
is set to LO or MED)
-
Set appliance to a higher temperature setting (MED or HI)
Heater
shuts off
automatically
Room is too warm
-
The heater has a built-in thermostat so it will shut off
automatically once the pre-set temperature is reached.
It will also turn on automatically if the room temperature
drops below the pre-set temperature. Preset temperature is
dependent on heater settings selected.
!
WARNING
42.17
SYMPTOM
PROBLEM
TEST SOLUTION
Dim or no fl ame
Bulb(s) are burnt out
Inspect the bulbs inside the fl ame generation cylinder drum and
replace them if necessary
Ember bed is not
glowing or dimming
Bulb(s) are burnt out
Inspect the ember bed bulbs and replace them if necessary
Appliance turns off
and will not turn on
Appliance has overheated
and safety device has
caused the thermal switch to
disconnect
Unplug the appliance, allow appliance to cool for 15 minutes,
then plug it back in
House circuit breaker has
tripped
Reset house circuit breaker
Appliance will not
come on when
switch is fl ipped to
ON
Appliance is not plugged
into an electrical outlet
Check plug and plug it in
Appliance has overheated
and safety device has
caused the thermal switch to
disconnect
Unplug the appliance, allow appliance to cool for 15 minutes,
then plug it back in
Remote control
does not work
Low batteries
Replace batteries in remote control
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A