* Within the appliance enclosure a 7” (178mm) clearance between the top of the vent pipe and combustible
materials is required. All other clearances within the enclosure, including where the vent pipe exits the
enclosure are subject to 2” (51mm) to the sides and bottom and 3” (76mm) to the top for horizontal and 1”
(25mm) for vertical.

** See venting section.

IMPORTANT:

THE FIRESTOP ASSEMBLY PROVIDED MUST BE USED WHEN THE VENT PIPES PASS

THROUGH ANY WALL OR ARE TERMINATED HORIZONTALLY.

TOP OF
APPLIANCE
OPENING

COMBUSTIBLE

NON-COMBUSTIBLE

TOP OF ENCLOSURE
(COMBUSTIBLE)

84” (2134mm)

MINIMUM

PLUS RISE **

28”

(711mm)

MINIMUM

68”

(1727mm)

MINIMUM

CEILING

96”

(2438mm)

MINIMUM

ENCLOSURE

HEIGHT

STEEL

STUD

FRAME

0” (0m) IF NON-
COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.