Avriq-srl module pinouts, Table b.1: avriq-srl module pinouts – Avocent 3100/3200 Manuel d'utilisation

Page 84

Advertising
background image

72 AutoView 3100/3200 Switch Installer/User Guide

To use History mode:

1.

Press

Ctrl-F9

. The mode will display as History.

2.

Press one of the following key combinations to perform the indicated action:

Home

: Move to the top of the buffer.

End

: Move to the bottom of the buffer.

Page Up

: Move up one buffer page.

Page Down

: Move down one buffer page.

Up Arrow

: Move up one buffer line.

Down Arrow

: Move down one buffer line.

Ctrl-F8

: Enters Configuration mode. The Configuration screen will appear.

Ctrl-F9

: While in Configuration mode, return to the previous screen with History

mode enabled.

Ctrl-F10

: While in Configuration mode, return to the previous screen with On-Line

mode enabled.

Ctrl-F11

: Clears the history buffer. If you choose this option, a warning screen will appear.

Press

Enter

to delete the history buffer, or

Escape

to cancel the action. The previous

screen will reappear.

3.

When finished, press

Ctrl-F10

to exit History mode and return to On-Line mode.

AVRIQ-SRL module pinouts

Table B.1 lists the pinouts for the AVRIQ-SRL module.

Table B.1: AVRIQ-SRL Module Pinouts

DB9-F

Pin

Host Signal Name Description

Signal Flow

SRL Signal Name Description

1

DCD - Data Carrier Detect

Out of SRL

DTR - Data Terminal Ready

2

RXD - Receive Data

Out of SRL

TXD - Transmit Data

3

TXD - Transmit Data

In to SRL

RXD - Receive Data

4

DTR - Data Terminal Ready

In to SRL

AutoView - Data Set Ready

5

GND - Signal Ground

N/A

GND - Signal Ground

6

AutoView - Data Set Ready

Out of SRL

DTR - Data Terminal Ready

7

RTS - Request to Send

In to SRL

CTS - Clear to Send

8

CTS - Clear to Send

Out of SRL

RTS - Request to Send

9

N/C - Not Connected

N/A

N/C - Not Connected

Advertising