STEINEL IS D360-120 Manuel d'utilisation
Page 8

www.steinel.net
(800) 852-4343
www.steinel.net
(800) 852-4343
Troubleshooting
No power at the
sensor
Lights do not
switch ON
breaker has tripped or
is not switched ON
break in wiring
or short circuit
light level setting is in
nighttime mode during
daytime operation
lamp burned out
power is off
breaker has tripped
detection zone not
correctly adjusted
reset breaker, check
wiring with voltage
tester
check for proper
wiring connections
adjust light level
setting
replace lamp
turn power on at
circuit breaker
reset breaker
readjust
Problem
Cause
Remedy
14
Troubleshooting
Lights do not
switch OFF
Lights keep
switching ON/OFF
Lights switch ON
without obvious
movement
abundant heat from the
fi xture’s lamps is within
the detection zone and
keeps lights on as a
result of temperature
change
continuous movement
in the detection zone
switched on light is
within detection zone
sensor is detecting
movement outside of
the lighting zone
mount sensor below
the lamps
readjust zone or
apply shroud
adjust detection
zone or apply
shrouds
adjust zone or apply
shrouds
Problem
Cause
Remedy
15