120/
230/

277 VAC
50/60Hz

Wireless

Voltage

Load

rating

Environment

RF

Dimensions

5 year warranty

UL and CUL Listed, RoHS Compliant, FCC and IC Compliant

120/230/277 VAC, 50/60 Hz

120 VAC: 0-800 watt ballast or Tungsten - 1/4 hp

230/277 VAC: 0-1200 watt ballast

IP20 rated, -4°F to +122°F, -20°C to +50°C

see page 3

3.92 x 3.92 x 1.56 in, 99.6 x 99.6 x 39.6 mm

nipple length .62 in (15.75 mm)

Specifi cations

1/2 inch threaded nipple

Lock nuts

Group address DIP switch

1

2

3

IP20

Fixture

or J Box

Mount

3

Product Overview RM 50

Product description
The RM 50 Wireless Receiver works with
STEINEL wireless sensors to extend group
lighting control without adding additional
sensors. It turns lighting on and off based on
detection from a wireless occupancy sensor
programmed to the same group.

The RM 50 mounts to a 1/2 inch knockout of
a lighting fi xture or junction box. The wireless
devices are grouped together via a DIP switch
address. Any wireless occupancy sensor will
switch all devices in a group ON when triggered.

ON

DIP

12

3

4

5

2

1

Mounting

• Receiver module mounts to a 1/2” knockout

of a lighting fi xture or junction box.

• Module must not be mounted within a metal

enclosure.

• Module can be mounted at any height and

is not affected by heating/cooling supply
ducts.

End of fi xture mounting -
RHB 300, RHB 200

End of fi xture mounting - RM 50

Placement guidelines -
RHB 300, RHB 200

Placement guidelines - RM 50

The RHB 300 and RHB 200 typically mount to
a 1/2” knockout at the end of a high/low bay
lighting fi xture. The sensor's lens should be
mounted below the bottom edge of the fi xture.

The EM 1 Extender Module is recommended
for use with the RHB 300 and RHB 200 if the
knockout at the end of the fi xture is located
greater than 1/2” from the bottom edge of the
fi xture.

The RM 50 typical mounts to a 1/2” knockout
at the end of a high/low bay lighting fi xture.
The receiver has no lens and therefore can be
mounted to any 1/2” knockout on the fi xture.

EM 1

Fixture

RHB Sensor

RHB Sensor

Fixture

RM 50

Fixture

• Sensor module mounts to a 1/2” knockout

of a lighting fi xture or junction box.

• Detection lens must have a clear,

unobstructed view of controlled area and
must project beyond the lamps.

• Sensor should be 6 to 8 feet away from

heating/cooling supply ducts.

• Ideal mounting height is up to 45 feet.
• Must be mounted on a stable platform.