Installation

Installation - ceiling mount

with threaded nipple

• Confirm power is off at the

circuit breaker

• Install power pack and

run low voltage wire to the
sensor location

• Run low voltage wires from

the sensor through the
provided threaded nipple and
snap threaded nipple in back
of sensor

• Cut 7/8” hold in ceiling tile
• Place threaded nipple

through hole in ceiling tile,
add washer and secure with
locknut

• Wire sensor to STEINEL

power pack

8

Ceiling Tile

Washer

Locknut

Sensor

Threaded Nipple

Operation

The IS 3180-24, IS 3360-24 and
IS 345-24 work with a STEINEL
power pack to control lighting
based on occupancy and daylight.

Manual operation
A line voltage or low voltage
switch may be used for manual off
control when the power pack is in
automatic on mode.
For manual on only operation, a
low voltage momentary switch is
required along with a STEINEL
power pack set in manual on
mode.

Light level function
The sensors incorporate a built-in
light level sensor which keeps
lighting off during daylight hours,
regardless of occupancy.

9

Threaded Nipple

Ceiling Tile

Locknut

Washer

Sensor