Installation
Installation - ceiling mount
with threaded nipple
• Confirm power is off at the
circuit breaker
• Install power pack and
run low voltage wire to the
sensor location
• Run low voltage wires from
the sensor through the
provided threaded nipple and
snap threaded nipple in back
of sensor
• Cut 7/8” hold in ceiling tile
• Place threaded nipple
through hole in ceiling tile,
add washer and secure with
locknut
• Wire sensor to STEINEL
power pack
8
Ceiling Tile
Washer
Locknut
Sensor
Threaded Nipple
Operation
The IS 3180-24, IS 3360-24 and
IS 345-24 work with a STEINEL
power pack to control lighting
based on occupancy and daylight.
Manual operation
A line voltage or low voltage
switch may be used for manual off
control when the power pack is in
automatic on mode.
For manual on only operation, a
low voltage momentary switch is
required along with a STEINEL
power pack set in manual on
mode.
Light level function
The sensors incorporate a built-in
light level sensor which keeps
lighting off during daylight hours,
regardless of occupancy.
9
Threaded Nipple
Ceiling Tile
Locknut
Washer
Sensor