Mounting the Housing: Existing Construction

1. Determine the desired location for the heater.

2. Drill a small hole through the ceiling at the chosen

location. Stick the end of a coat hanger through the hole
into the attic to help locate the spot in the attic.

3. Check the chosen area from above to make sure that the

wiring can be installed and that the installation will not
interfere with any existing wiring.

4. In the attic, place the housing between ceiling joists at

the chosen location. Mark the ceiling for cutout by using
the heater housing’s flange as a template. Make the
cutout.

5. Install the housing in the opening using hanger bars or

mounting tabs as described above.

6. Remove the desired electrical knockout from the junction

box in the housing.

Ducting

NOTE: All ducting must comply with local building codes.
Vented fans must always be ducted to the outdoors.

1. Make sure you have removed any tape which may be

holding the outlet damper closed. Connect the correct
ducting to the housing collar (4” round outlet on heater
housing).

2. Secure in place using duct tape or a screw clamp. To

ensure maximum air delivery keep the length of duct and
number of elbows to a minimum.

Electrical Wiring

(Refer to Fig. 2)

CAUTION: Make sure the power is switched off before
making this installation.

NOTE: All wiring must comply with local and national
codes. You must ground this unit.

NOTE: This unit must be wired on a separate 20 amp
circuit.

You will have to get the heater’s wire compartment cover
from the carton.

1. Run 3 wires and a ground (12GA) from the heater box to

the wall box (location of the switches). Make sure you
identify which wire is for which component. The following
is the colour code in the heater’s junction box: Blue wire =
Fan, Red wire = Heater, White wire = Neutral. Connect the
ground wire to the green ground screw in the heater’s
junction box.

2. Switches should be installed in an approved outlet box.

Make sure you connect the ground in the outlet box as
well.

3. Replace the junction box cover in the heater housing

when the wiring is complete.

Completing the Installation

You will need to get the grill from the carton.

1. Once you have mounted the housing, connected the

ducting, and completed the wiring you can install the
grill. First plug in the fan and heater into the heater’s wire
compartment cover’

3. The heater’s lens flips down, release the lens by pushing

on the 2 tabs which hold it in place in the grill.

4. Secure the grill and lens to the heater housing via 2

screws (provided). Flip the lens back into position.

AIR KING LIMITED, 110 GLIDDEN ROAD, BRAMPTON, ONTARIO, CANADA; TEL. 905-456-2033, 1-800-465-7300, FAX. 905-456-1015

INSTALLATION

INSTRUCTIONS

HEATER

ELECTRICAL BOX

HOUSE

ELECTRICAL BOX

AK905 WIRING DIAGRAM

120V 60HZ

HEATER

FAN

GROUND

GROUND

DOUBLE

SWITCH

BLK

WHT

GRD

RED

RED

WHT

WHT

BLUE

Fig 2.