Power-Management

The three cooking zones front left,
front right and back right together
have a maximum possible power
available to them.
If it looks like the maximum power
of all three cooking zones is going
to be exceeded, for example by
turning on an additional cooking
zone or by turning up a heat setting, the Power Management automat-
ically reduces the power of another cooking zone. The power of the
cooking zone that has been switched on for the longest time is re-
duced. For two minutes the indicator for this cooking zone changes be-
tween the previously set heat setting and the maximum possible heat
setting at this time. After two minutes the actual heat setting is dis-
played.
The following table shows the distribution of the maximum possible
heat settings when all three cooking zones are on at the same time.

1st cooking zone

2nd cooking zone

1 - 6

8

9

7

7

9

8

8

8