INDUCTION COOKTOP INSTALLATION INSTRUCTIONS

H

G

F

L

Figure 2 – COUNTERTOP CUTOUT OPENING

CAUTION

To eliminate the risk of

burns or fi re by reaching over heated
surfaces, cabinet storage space located
above the cooktop should be avoided.
If cabinet storage is provided, risk can
be reduced by installing a range hood
that projects horizontally a minimum of
5" (12.7 cm) beyond the bottom of the
cabinets.

* Letters on this fi gure refer to chart

on front page except for J and K.

Overhead Cabinet Should Not Exceed a
Maximum Depth of 13" (33 cm)

30" (76.2 cm) Min. Clearance
Between the Top of the
Cooking Platform and the
Bottom of an Unprotected
Wood or Metal Cabinet

24" (61 cm) Min. when Bottom
of Wood or Metal Cabinet
is Protected by Not Less
Than 1/8" (0.3 cm) Flame
Retardant Millboard Covered
With Not Less Than No. 28
MGS Sheet Steel, 0.015" (0.4
mm) Stainless Steel, 0.024"
(0.6 mm) Aluminum or 0.020"
(0.5 mm) Copper.

2½" (6.4 cm) Min. From
Edge of Cutout to Front
Edge of Countertop

Approximate Location of
Junction Box

18"

(45.7 cm)

It is not recommended to use
drawer underneath cooktop.
Empty space is needed for
installation purpose.

J

Min. From Edge of

Cooktop to Nearest
Combustible Wall
(Either Side of Unit).

12"

(30.5 cm)

10"

( 25.4 cm)

Min.

K

Min. Recommended

Distance Between Rear
Edge of Cutout and
Nearest Combustible
Surface Above
Countertop

24"

(61 cm)

Model and Serial Number Location

The serial plate is located under the cooktop.

When ordering parts for or making inquires about
your cooktop, always be sure to include the model
and serial numbers and a lot number or letter from the
serial plate on your cooktop.

Serial plate is located
under the burner box
of cooktop.

MODEL

J

K

L

30"

2" (5.1cm)

1 1/2" (3.8cm)

30"

(76.2cm)

36"

2" (5.1cm)

2" (5.1cm)

36"

(91.4cm)

Advertising