INSTALLATION OF SS-2007 SERIES STOPPER

®

STATION

All specifications and information shown were current as of publication, and are subject to change without notice.

10278IS APRIL2011

NO - NORMALLY OPEN

NC - NORMALLY CLOSED

C - COMMON

10A, 1/2 HP, 125/250 VAC
6A, 30 VDC
MODELS WITH LT-1 TIMER:
FORM C CONTACTS RATED
120 VAC, 3A
28 VDC, 3A

TYPE

BASE

VOLTS

WATTS

AMPS

RADION PT. NO.
OR EQUIVALENT

AVERAGE

LIFE (Hrs.)

FILAMENT

T3-1/4
WEDGE

6.3

1.57

0.25

3000

FILAMENT

T3-1/4
WEDGE

14

1.12

0.08

15,000

FILAMENT

T3-1/4
WEDGE

28

1.68

0.06

2500

50N8079 / #555

#658

50N8109 / #656

TERMINAL BLOCK LEGEND SWITCH RATINGS CHART

LAMP CHART

Safety Technology International, Inc.

2306 Airport Road • Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Fax: 248-673-1246
Toll Free: 800-888-4784 • E-mail: [email protected]
Web: www.sti-usa.com

Safety Technology International (Europe) Ltd.

Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch
Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only)
E-mail: [email protected] • Web: www.sti-europe.com

VIEW SHOWING INSTALLATION OF LAMP

HOLDER TO BUTTON ASSEMBLY

MULTIPLE DEVICES N/C LIGHT MAINTAINED SERIES WIRING

SINGLE DEVICE LIGHT

MAINTAINED FOR LAMP VOLTAGE

SEE CHART BELOW

MULTIPLE DEVICES

N/O LIGHT

MAINTAINED

PARALLEL WIRING

*SS-2007/LTLUL NOTES: For access control installations, power for the LT-1UL Timer must be supplied by a power source listed to UL294. When used for access
control, this device shall be used as part of an access controlled egress door system. It is up to the local AHJ to allow use of this device in place of an automatic sensor.
For higher security installations, lower time limits should be used. For SS-2007/LTUL the enclosed timer is to be used and installed per the enclosed LT-1UL installation
sheet. SS-2007/LTUL maximum rating 30 VDC 3A.

Electronic warranty form at www.sti-usa.com/wc14

INSERT BUTTON ASSEMBLY INDEXING TABS
INTO LAMP HOLDER SLOTS THEN TWIST CLOCKWISE
AS SHOWN TO LOCK.

BACKPLATE ASSEMBLY

+

# 1

# 2

_

# 3

L

TO DEVICES

L

L

O

+

O

L

O

L



+

_

L

C

N/O

TO DEVICES

C

N O

+

_

L

# 1

C

N O

L

# 2

C

N O

L

# 3

TO DEVICES

S



O

+

SWITCH ASSEMBLY

SEE VIEW BELOW

BURNDY FORK
TERMINAL #TP14-6F
OR EQUIVALENT

10112 SWITCH ASSEMBLY
WITH SCREW TERMINALS
SEE SWITCH RATINGS CHART

(

)

C

NO

NC

+

(

)

+

-

(

)

LAMP HOLDER
(PART OF SWITCH
ASSEMBLY)

14-16 AWG

BURNDY SPADE

TERMINAL #NC14F2590

OR EQUIVALENT

LAMP (SEE CHART)

STANDARD #656

10277 SHELL WHITE

10272-S BACKPLATE

ASSEMBLY

(SMOKE COLOR ONLY)

BUTTON ASSEMBLY
10111 (GREEN)
10110 (RED)

10271 STATION HOUSING
RED, GREEN, WHITE, YELLOW
AND BLUE

STATION LABEL

19001 SCREW #8-32 X 3/8 in.
(1) PROVIDED

19015 ALLEN WRENCH
3/32 (1) PROVIDED

19021 GROUND LUG
#10-32 x 3/8 in.
(1) PROVIDED

19010 SCREWS
#6-32 x 1 in.
BACKPLATE TO
ELECTRICAL BOX
(2) PROVIDED

RETAINING NUT

PU

SH

REMARQUES POUR *SS-2**7/LT1-UL: Pour les installations de contrôle d’accès, l’alimentation de la minuterie LT-1UL doit être fournie par une source homologuée UL294. Lorsque
cet appareil est utilisé aux fins de contrôle d’accès, il doit faire partie d’un système de porte de sortie à accès contrôlé. Il incombe donc à l’AHJ local d’autoriser l’utilisation de cet
appareil au lieu d’un capteur automatique. Pour les installations de sécurité plus renforcée, des délais inférieurs doivent être utilisés. Pour les modèles SS-2**7/LT1-UL, la minuterie
intégrée doit être installée et utilisée suivant la fiche d’installation LT-1UL fournie. La cote maximale des modèles * SS-2**7/LT1-UL est de 30 VCC 3A.

Advertising
Ce manuel est liée aux produits suivants: