BLAZE 800 D/G
SPECIFICATIONS
BLAZE 800G-
BECKETT (NG/LP)
BLAZE 800D-
BECKETT (OIL)
Burner Make & Model
Beckett CG10A
Beckett CF800
Voltage
208V/240V
208V/240V
Input (BTU/h)
800,000
800,000
Heated Air CFM/AMPS for
Fan speeds:
3-CFM/1PH Amps/3PH
Amps
2-CFM/1PH Amps/3PH
Amps
1-CFM/1PH Amps/3PH
Amps
3-
10,000/16A/8,5A
2-
8,500/14A/7,5A
1-
7,000/13A/7A
3-
10,000/16A/8,5A
2-
8,500/14A/7,5A
1-
7,000/13A/7A
MOTOR HP
4
4
Ductability
200ft
200ft
Outlet Duct Size
24” or (4) X 12”
24” or (4) X 12”
Inlet Duct Size
24”
24”
Gas Conversion
Remove Orifice as
per instructions
found in manual.
Propane orifice
part # 3246707U,
O‐ring part #
3226409U,
restrictor inside
diameter 0.482
N/A
Manifold pressure “W.C.
3
N/A
Minimum/Maximum
Supply Pressure
“W.C.
3/14
N/A
Nozzle
N/A
4.5 GPH X 60 B